Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2000 Oct;46(10):1626-30.

Plasma nitric oxide concentrations and nitric oxide synthase gene polymorphisms in coronary artery disease

Affiliations
  • PMID: 11017941

Plasma nitric oxide concentrations and nitric oxide synthase gene polymorphisms in coronary artery disease

Y Yoon et al. Clin Chem. 2000 Oct.

Erratum in

  • Clin Chem 2001 Jan;47(1):151

Abstract

Background: Plasma NOx (nitrate and nitrite) is a stable end product of the vasodilator NO. Several polymorphisms in the endothelial constitutive NO synthase (ecNOS) gene have been reported, including the 4a/4b VNTR polymorphism in intron 4, the E298D mutation in exon 7, and the G10-T polymorphism in intron 23. The aims of this study were to examine plasma NOx in patients with coronary artery disease (CAD) and to assess the association between plasma NOx concentrations and the three ecNOS gene polymorphisms.

Methods: Plasma NOx was measured in samples from 128 healthy controls and from 110 CAD patients at least 2 months after myocardial infarction. Three genetic polymorphisms that are known or have been suggested to be associated with plasma NOx concentration were also analyzed by PCR-restriction fragment length polymorphism.

Results: Median plasma NOx was significantly higher (P <0.001) in CAD patients (95.9 micromol/L) than in controls (73.8 micromol/L). Furthermore, the median plasma NOx was significantly higher (P <0.001) in hypertensive CAD patients (116.0 micromol/L) than in controls and normotensive CAD patients (86.0 micromol/L). The G-allele frequency of the G10-T polymorphism in intron 23 was significantly higher in CAD patients than in controls. Other polymorphisms showed no differences in allelic frequencies among the control and CAD groups. In controls, individuals with the E298D mutation in exon 7 (136.1 micromol/L) showed significantly higher (P = 0.001) median plasma NOx than those without this mutation (64.5 micromol/L).

Conclusions: Plasma NOx was higher in hypertensive CAD patients than in normotensive CAD patients and controls. The E298D polymorphism of the ecNOS gene was associated with increased plasma NOx. Further study is needed to understand the gene expression and enzyme activity of ecNOS and their association with genotypes.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources