Long-term outcomes of minor dissection at the edge of stents detected with intravascular ultrasound
- PMID: 11018205
- DOI: 10.1016/s0002-9149(00)01085-7
Long-term outcomes of minor dissection at the edge of stents detected with intravascular ultrasound
Abstract
We evaluated the influences of minor edge dissections on late angiographic in-stent restenosis in 327 patients with 348 lesions (281 lesions without edge dissection and 67 lesions [19.3%] with edge dissection); the angiographic restenosis rate was 29.9% in the lesions with edge dissections versus 25.3% without edge dissections (p = 0.540). The minor non-flow-limiting dissections at the edge of stents may not be associated with the development of late angiographic in-stent restenosis.
Similar articles
-
Long-term outcomes of minor plaque prolapsed within stents documented with intravascular ultrasound.Catheter Cardiovasc Interv. 2000 Sep;51(1):22-6. doi: 10.1002/1522-726x(200009)51:1<22::aid-ccd6>3.0.co;2-i. Catheter Cardiovasc Interv. 2000. PMID: 10973013
-
Results of the Jostent coronary stent graft implantation in various clinical settings: procedural and follow-up results.Catheter Cardiovasc Interv. 2002 Jul;56(3):353-60. doi: 10.1002/ccd.10223. Catheter Cardiovasc Interv. 2002. PMID: 12112888
-
Natural history of intravascular ultrasound-detected edge dissections from coronary stent deployment.Am Heart J. 2000 Jan;139(1 Pt 1):59-63. doi: 10.1016/s0002-8703(00)90309-0. Am Heart J. 2000. PMID: 10618563
-
Stenting the stent: alternative strategy for treating in-stent restenosis.Cathet Cardiovasc Diagn. 1996 Dec;39(4):377-82. doi: 10.1002/(SICI)1097-0304(199612)39:4<377::AID-CCD12>3.0.CO;2-A. Cathet Cardiovasc Diagn. 1996. PMID: 8958427 Review.
-
Understanding intravascular ultrasound.Am J Nurs. 1996 Jun;96(6):40-3; quiz 44. doi: 10.1097/00000446-199606000-00042. Am J Nurs. 1996. PMID: 8651334 Review.
Cited by
-
Lipid rich plaque, female gender and proximal coronary stent edge dissections.J Thromb Thrombolysis. 2013 Nov;36(4):507-13. doi: 10.1007/s11239-013-0882-3. J Thromb Thrombolysis. 2013. PMID: 23378150 Clinical Trial.
-
Impact of stent edge dissection detected by optical coherence tomography after current-generation drug-eluting stent implantation.PLoS One. 2021 Nov 4;16(11):e0259693. doi: 10.1371/journal.pone.0259693. eCollection 2021. PLoS One. 2021. PMID: 34735528 Free PMC article.
-
Predictors and incidence of stent edge dissections in patients with type 2 diabetes as determined by optical coherence tomography.Int J Cardiovasc Imaging. 2013 Aug;29(6):1237-47. doi: 10.1007/s10554-013-0213-y. Epub 2013 Apr 5. Int J Cardiovasc Imaging. 2013. PMID: 23558468
-
Optimization of stent deployment by intravascular ultrasound.Korean J Intern Med. 2012 Mar;27(1):30-8. doi: 10.3904/kjim.2012.27.1.30. Epub 2012 Feb 28. Korean J Intern Med. 2012. PMID: 22403496 Free PMC article. Review.
-
Findings of intravascular ultrasound during acute stent thrombosis.Heart. 2004 Dec;90(12):1455-9. doi: 10.1136/hrt.2003.026047. Heart. 2004. PMID: 15547028 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources