Long-term outcomes of minor dissection at the edge of stents detected with intravascular ultrasound
- PMID: 11018205
- DOI: 10.1016/s0002-9149(00)01085-7
Long-term outcomes of minor dissection at the edge of stents detected with intravascular ultrasound
Abstract
We evaluated the influences of minor edge dissections on late angiographic in-stent restenosis in 327 patients with 348 lesions (281 lesions without edge dissection and 67 lesions [19.3%] with edge dissection); the angiographic restenosis rate was 29.9% in the lesions with edge dissections versus 25.3% without edge dissections (p = 0.540). The minor non-flow-limiting dissections at the edge of stents may not be associated with the development of late angiographic in-stent restenosis.