Performance evaluation of a new chemiluminescent cardiac troponin I assay

Affiliations
Comparative Study

Performance evaluation of a new chemiluminescent cardiac troponin I assay

A Dasgupta et al. J Clin Lab Anal. 2000.

Abstract

Cardiac troponin I is a marker for diagnosis of myocardial damage. Several immunoassays are currently available for determination of concentrations of troponin I in serum. We evaluated a chemiluminescent assay for troponin I using ACS:180 automated analyzer (Bayer Diagnostics). We compared our results with two other immunoassays using the OPUS Magnum (OPUS troponin I assay, Dade Behring) and AxSYM (microparticle enzyme immunoassay, Abbott) analyzers. The within-run and between-run CVs were less than 5% for all three levels of controls. The chemiluminescent assay for troponin I was linear up to a serum troponin I concentration of 50 ng/mL and the detection limit was 0.1 ng/mL of troponin. A good correlation between troponin I concentration measured by the chemiluminescent assay (y axis) and the microparticle enzyme immunoassay (MEIA) (x axis) was observed, although the concentrations of troponin I in individual specimens were approximately four times higher, when measured by the MEIA assay, than those measured by chemiluminescent assay. The correlation coefficient was 0.98 with the regression equation y = 0.22x + 1.125. We also observed a good correlation in troponin I concentrations obtained by the chemiluminescent assay (y axis) and OPUS troponin I assay (x axis). The correlation coefficient was 0.96 and the regression equation was y = 0.79x - 0.52. The correlation coefficient was 0.93 when we compared troponin I concentrations obtained by the OPUS assay (x axis) with the corresponding concentrations obtained by the MEIA assay (y axis). The corresponding regression equation was y = 0.25x + 3.5. We conclude that the chemiluminescent troponin I assay showed good analytical performance.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Dorogy ME, Hooks GS, Cameron RW, Davis RC. 1995. Clinical and angiographic correlates of normal creatinine kinase with increased MB isoenzymes in possible acute myocardial infarction. Am Heart J 130:211–217. - PubMed
    1. Hong RA, Litch JD, Wei Y, et al. 1986. Elevated CK‐MB with normal total creatinine kinase in suspected myocardial infarction: associated clinical findings and early prognosis. Am Heart J 111:1041–1046. - PubMed
    1. Osborn LA, Rossum A, Standefer J, et al. 1995. Evaluation of CK and CK‐MB in alcohol abuse subjects with heavy consumption. Cardiology 86:130–134. - PubMed
    1. Shen CC, Hung CJ, Wu CC, Huang HW, Ho WM. 1999. Rhabdomyolysis‐induced acute renal failure after morphine overdose—a case report. Acta Anaesthesoil Sin 37:159–162. - PubMed
    1. Leszyk J, Dumaswala R, Porter JD, et al. 1988. Amino acid sequence of bovine cardiac troponin I. Biochemistry 27:2821–2827. - PubMed

Publication types