Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2000;51(2):35-40.

[Changes in myopic refractive errors after 9 months of extensive wear of hydrogel lenses with high oxygen permeability and compared with those with low permeability]

[Article in Romanian]
Affiliations
  • PMID: 11021121
Clinical Trial

[Changes in myopic refractive errors after 9 months of extensive wear of hydrogel lenses with high oxygen permeability and compared with those with low permeability]

[Article in Romanian]
M Filip et al. Oftalmologia. 2000.

Abstract

Background: A small but significant increase in myopia after extended wear of low oxygen permeability (Dk) hydrogel lenses has been previously reported; however, the specific impact of hypoxia on refractive status and corneal curvature with extended wear are not well documented. THE PURPOSE of this study was to compare the refractive changes induced over a period of 9 months' extended wear with high-Dk fluorosiloxane hydrogel lenses and low-Dk hydrogel lenses.

Methods: Adapted daily wear contact lens wearers were randomly assigned to one of two groups. The low-Dk group wore etafilcon A (Dk = 28) for up to 7 days and 6 nights and the high-Dk group wore lotrafilcon A (Dk = 140) for up to 30 days and nights. Refractive error and corneal curvature were measured at 3-month intervals over 9 month of extended wear.

Results: The etafilcon A group demonstrated an average increase in myopia of 0.30 D over the 9 months period; however, no change in spherical myopic correction was measured in the lotrafilcon A group. The cylindrical component did not change in either group. A stratified analysis revealed a greater increase in myopia for low myopes than moderate myopes in the etafilcon A group but no difference in the lotrafilcon A group. Keratometric analysis revealed no change in the etafilcon A group and a small degree of central corneal flattering in both major meridians of 0.35 D in the lotrafilcon A group.

Conclusions: Nine months of extended wear of low-Dk lenses is associated with a small degree of myopic progression in adult myopes that appears to be reversible. Wearing fluorosiloxane-hydrogel lenses of high-Dk had no impact on refractive error and may be associated with a small degree of central corneal flattering.

PubMed Disclaimer