Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2000 Aug;12(5):343-9.
doi: 10.1016/s0952-8180(00)00167-7.

Preoperative clonidine attenuates stress response during emergence from anesthesia

Affiliations
Clinical Trial

Preoperative clonidine attenuates stress response during emergence from anesthesia

M P Zalunardo et al. J Clin Anesth. 2000 Aug.

Abstract

Study objectives: To investigate whether a single preoperative IV dose of clonidine blunts the hemodynamic and hyperadrenergic responses not only to intubation, but also to extubation.

Design: Randomized, double-blind, placebo-controlled study.

Patients: 29 ASA physical status I and II patients (ages 18-65) who were scheduled for noncardiac, elective surgery. Patients were randomly assigned to either receive clonidine 3 microg/kg IV immediately before anesthesia induction or placebo.

Interventions: Insertion of a 14 G cannula in a large cubital vein for the determination of plasma catecholamines using local anesthesia. Insertion of a radial artery catheter for measuring blood pressure (BP) using local anesthesia. Transthoracic echocardiography to determine cardiac output (CO).

Measurements: Heart rate (HR), mean arterial pressure (MAP), CO, and plasma catecholamine concentrations. Measurements were performed: before induction (baseline), during intubation, 10 min after intubation, after surgery, during extubation, and 10 min after extubation.

Main results: During intubation MAP, HR, and CO were lower in the clonidine group. Compared with baseline measurements, MAP and CO increased less in the clonidine group during intubation. During extubation, MAP was lower in the clonidine group. CO and MAP increased less as compared with baseline measurements in the clonidine group. Compared with the measurements after surgery CO less in the clonidine group during extubation (p < 0.05 for all results).

Conclusions: A single preoperative IV dose of clonidine (3 microg/kg) blunts the hemodynamic responses due to extubation in noncardiac surgery of intermediate duration.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources