Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention
- PMID: 11028462
- DOI: 10.1016/s0735-1097(00)00859-7
Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention
Abstract
Prosthesis-patient mismatch is present when the effective orifice area of the inserted prosthetic valve is less than that of a normal human valve. This is a frequent problem in patients undergoing aortic valve replacement, and its main hemodynamic consequence is the generation of high transvalvular gradients through normally functioning prosthetic valves. The purposes of this report are to present an update on the concept of aortic prosthesis-patient mismatch and to review the present knowledge with regard to its impact on hemodynamic status, functional capacity, morbidity and mortality. Also, we propose a simple approach for the prevention and clinical management of this phenomenon because it can be largely avoided if certain simple factors are taken into consideration before the operation.
Similar articles
-
Hemodynamic evaluation and midterm outcome of aortic valve replacement with size 19 Perimount prosthetic valve.Ann Thorac Surg. 2008 Dec;86(6):1799-803. doi: 10.1016/j.athoracsur.2008.08.019. Ann Thorac Surg. 2008. PMID: 19021980
-
Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement.Ann Thorac Surg. 2005 Feb;79(2):505-10. doi: 10.1016/j.athoracsur.2004.04.042. Ann Thorac Surg. 2005. PMID: 15680824 Clinical Trial.
-
Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.Circ Cardiovasc Interv. 2017 Jul;10(7):e005216. doi: 10.1161/CIRCINTERVENTIONS.117.005216. Circ Cardiovasc Interv. 2017. PMID: 28698291
-
Patient-prosthetic aortic valve mismatch: role of the echocardiographer.Echocardiography. 2005 Apr;22(4):365-6. doi: 10.1111/j.1540-8175.2005.40015.x. Echocardiography. 2005. PMID: 15839996 Review. No abstract available.
-
Prosthesis-patient mismatch: an update.Curr Cardiol Rep. 2011 Jun;13(3):250-7. doi: 10.1007/s11886-011-0172-7. Curr Cardiol Rep. 2011. PMID: 21350829 Review.
Cited by
-
Update on aortic valve prosthesis-patient mismatch in Japan.Gen Thorac Cardiovasc Surg. 2013 Dec;61(12):669-75. doi: 10.1007/s11748-013-0243-3. Epub 2013 Apr 13. Gen Thorac Cardiovasc Surg. 2013. PMID: 23585189 Review.
-
Sutureless valves fit/perform well in a small aortic annulus.Ann Cardiothorac Surg. 2020 Sep;9(5):414-416. doi: 10.21037/acs.2020.04.02. Ann Cardiothorac Surg. 2020. PMID: 33102181 Free PMC article. No abstract available.
-
Evolving Devices and Material in Transcatheter Aortic Valve Replacement: What to Use and for Whom.J Clin Med. 2022 Jul 30;11(15):4445. doi: 10.3390/jcm11154445. J Clin Med. 2022. PMID: 35956061 Free PMC article. Review.
-
Small Annulus, Big Impact on TAVR Patients?JACC Asia. 2025 Feb;5(2):255-257. doi: 10.1016/j.jacasi.2024.11.009. Epub 2025 Feb 4. JACC Asia. 2025. PMID: 39967215 Free PMC article.
-
Implications of Coexisting Aortic Regurgitation in Patients With Aortic Stenosis.JACC Asia. 2021 Jun 15;1(1):105-111. doi: 10.1016/j.jacasi.2021.05.004. eCollection 2021 Jun. JACC Asia. 2021. PMID: 36338366 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources