Digital overlay technique for documenting toric intraocular lens axis orientation
- PMID: 11033397
- DOI: 10.1016/s0886-3350(00)00442-9
Digital overlay technique for documenting toric intraocular lens axis orientation
Abstract
Purpose: To describe a digital overlay technique for documenting toric intraocular lens (IOL) axis alignment.
Setting: Jules Stein Eye Institute and the Department of Ophthalmology, University of California at Los Angeles School of Medicine, Los Angeles, California, USA.
Methods: Digital overlay imaging was used to evaluate the alignment of Staar toric IOLs in 4 eyes of 3 patients who had regular corneal astigmatism at the time of cataract surgery. Lens axes were determined by computerized analysis of digitally scanned retroillumination photographs. A stock digital image of a Staar AA4203TF toric IOL was superimposed on corneal topography images to document IOL alignment with the steep corneal meridian.
Results: Digital overlay images demonstrated that 3 IOLs in the sample group were within 5 degrees and 1 was within 20 degrees of the intended axis at the time of the final postoperative examination. Slitlamp lens axis estimations were 3 to 18 degrees different from that determined by this technique.
Conclusion: Digital overlay imaging of correctly oriented toric IOLs on computerized corneal topography maps represents an intuitive, accurate, and visually appealing method of documenting toric IOL axis alignment.