Comparison of the new millipore HC with conventional membrane filters for the enumeration of fecal coliform bacteria
- PMID: 1103735
- PMCID: PMC187250
- DOI: 10.1128/am.30.4.697-699.1975
Comparison of the new millipore HC with conventional membrane filters for the enumeration of fecal coliform bacteria
Abstract
Fecal coliform recoveries were determined for six types of membrane filters using 65 nonchlorinated water samples. Results showed that the membranes could be ranked in order of decreasing recovery as follows: Millipore HC greater than Gelman greater than Johns-Manville approximately Sartorius greater than Millipore HA greater than Schleicher & Schuell.
Similar articles
-
Comparison of the surface structure, metal binding, and fecal coliform recoveries of nine membrane filters.Appl Environ Microbiol. 1977 Jul;34(1):69-79. doi: 10.1128/aem.34.1.69-79.1977. Appl Environ Microbiol. 1977. PMID: 329763 Free PMC article.
-
Evaluation of millipore HA and HC membrane filters for the enumeration of indicator bacteria.Appl Environ Microbiol. 1976 Aug;32(2):300-2. doi: 10.1128/aem.32.2.300-302.1976. Appl Environ Microbiol. 1976. PMID: 788641 Free PMC article.
-
Influence of coliform source on evaluation of membrane filters.Appl Microbiol. 1975 Nov;30(5):727-30. doi: 10.1128/am.30.5.727-730.1975. Appl Microbiol. 1975. PMID: 1106318 Free PMC article.
-
Comparison of Gelman and Millipore membrane filters for enumerating fecal coliform bacteria.Appl Microbiol. 1973 Sep;26(3):332-6. doi: 10.1128/am.26.3.332-336.1973. Appl Microbiol. 1973. PMID: 4584578 Free PMC article.
-
Statistical analysis of the recovery of coliform organisms on Gelman and Millipore membrane filters.Appl Microbiol. 1974 Oct;28(4):605-7. doi: 10.1128/am.28.4.605-607.1974. Appl Microbiol. 1974. PMID: 4608420 Free PMC article.
Cited by
-
Comparison of the surface structure, metal binding, and fecal coliform recoveries of nine membrane filters.Appl Environ Microbiol. 1977 Jul;34(1):69-79. doi: 10.1128/aem.34.1.69-79.1977. Appl Environ Microbiol. 1977. PMID: 329763 Free PMC article.
-
Membrane filter method for recovery of fecal coliforms in chlorinated sewage effluents.Appl Environ Microbiol. 1976 Oct;32(4):547-52. doi: 10.1128/aem.32.4.547-552.1976. Appl Environ Microbiol. 1976. PMID: 791122 Free PMC article.
-
New screening test to determine the acceptability of 0.45-micron membrane filters for analysis of water.Appl Environ Microbiol. 1990 Jan;56(1):54-64. doi: 10.1128/aem.56.1.54-64.1990. Appl Environ Microbiol. 1990. PMID: 2106827 Free PMC article.
-
Evaluation of millipore HA and HC membrane filters for the enumeration of indicator bacteria.Appl Environ Microbiol. 1976 Aug;32(2):300-2. doi: 10.1128/aem.32.2.300-302.1976. Appl Environ Microbiol. 1976. PMID: 788641 Free PMC article.
-
Membrane filter technique for the quantification of stressed fecal coliforms in the aquatic environment.Appl Environ Microbiol. 1977 Jul;34(1):42-6. doi: 10.1128/aem.34.1.42-46.1977. Appl Environ Microbiol. 1977. PMID: 329762 Free PMC article.
References
-
- Appl Microbiol. 1975 Oct;30(4):685-91 - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources