Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2000 Oct;106(5):1036-45; discussion 1046-8.
doi: 10.1097/00006534-200010000-00013.

A randomized prospective study of polyglycolic acid conduits for digital nerve reconstruction in humans

Affiliations
Clinical Trial

A randomized prospective study of polyglycolic acid conduits for digital nerve reconstruction in humans

R A Weber et al. Plast Reconstr Surg. 2000 Oct.

Abstract

This article reports the first randomized prospective multicenter evaluation of a bioabsorbable conduit for nerve repair. The study enrolled 98 subjects with 136 nerve transections in the hand and prospectively randomized the repair to two groups: standard repair, either end-to-end or with a nerve graft, or repair using a polyglycolic acid conduit. Two-point discrimination was measured by a blinded observer at 3, 6, 9, and 12 months after repair. There were 56 nerves repaired in the control group and 46 nerves repaired with a conduit available for follow-up. Three patients had a partial conduit extrusion as a result of loss of the initially crushed skin flap. The overall results showed no significant difference between the two groups as a whole. In the control group, excellent results were obtained in 43 percent of repairs, good results in 43 percent, and poor results in 14 percent. In those nerves repaired with a conduit, excellent results were obtained in 44 percent, good results in 30 percent, and poor results in 26 percent (p = 0.46). When the sensory recovery was examined with regard to length of nerve gap, however, nerves with gaps of 4 mm or less had better sensation when repaired with a conduit; the mean moving two-point discrimination was 3.7 +/- 1.4 mm for polyglycolic acid tube repair and 6.1 +/- 3.3 mm for end-to-end repairs (p = 0.03). All injured nerves with deficits of 8 mm or greater were reconstructed with either a nerve graft or a conduit. This subgroup also demonstrated a significant difference in favor of the polyglycolic acid tube. The mean moving two-point discrimination for the conduit was 6.8 +/- 3.8 mm, with excellent results obtained in 7 of 17 nerves, whereas the mean moving two-point discrimination for the graft repair was 12.9 +/- 2.4 mm, with excellent results obtained in none of the eight nerves (p < 0.001 and p = 0.06, respectively). This investigation demonstrates improved sensation when a conduit repair is used for nerve gaps of 4 mm or less, compared with end-to-end repair of digital nerves. Polyglycolic acid conduit repair also produces results superior to those of a nerve graft for larger nerve gaps and eliminates the donor-site morbidity associated with nerve-graft harvesting.

PubMed Disclaimer

Comment in

Substances

LinkOut - more resources