Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2000 Sep-Oct;24(5):683-7.
doi: 10.1097/00004728-200009000-00003.

MRI of the pulmonary veins: comparison between 3D MR angiography and T1-weighted spin echo

Affiliations
Comparative Study

MRI of the pulmonary veins: comparison between 3D MR angiography and T1-weighted spin echo

F Pilleul et al. J Comput Assist Tomogr. 2000 Sep-Oct.

Abstract

Objective: The purpose was to determine the ability of three-dimensional (3D) magnetic resonance (MR) angiography to depict normal pulmonary veins in comparison with spin-echo MR imaging.

Materials and methods: MR imaging of 40 patients with cardiovascular disease were reviewed. Patients with known pulmonary venous abnormalities were excluded. Using a standard GE 1.5-T magnet, axial T1-weighted spin-echo 5-mm-thick contiguous slices and 3D MR angiography (contiguous slice thickness of 2.5-3.5 mm, 20-30 c.c. of gadolinium bolus at 1-1.5 c.c./sec, 32-43-second breath-hold, coronal and sagittal plane acquisition) were evaluated retrospectively on separate occasions by two experienced radiologists. Multiplanar imaging projection was used for the identification of pulmonary veins. Each lung was considered to have two drainage veins: a superior vein and an inferior vein. Identification of a pulmonary vein was made by visualizing a connection with the left atrium.

Results: 143 pulmonary veins (87.5% +/-5.2) were identified at the level of the left atrium on T1-weighted spin-echo images, and 157 (98.1% +/-1.9) were identified on 3D MR angiography (p<0.01). Overall we identified by T -weighted spin-echo imaging 36 right upper, 38 right lower, 27 left upper, and 38 left lower pulmonary veins. By 3D MR angiography, we identified 38 right upper, 40 right lower, 39 left upper, and 40 left lower pulmonary veins. All four pulmonary veins were detected in 22 patients on spin-echo imaging (55%) and in 37 patients (92.5%) on 3D MR angiography (chi = 3.81, p<0.05).

Conclusion: A significant difference is demonstrated between 3D MR angiography and spin-echo MR imaging in identifying normal pulmonary veins. MR angiography provides a complete view of normal pulmonary venous anatomy and could be a valuable tool for the assessment of abnormal pulmonary venous drainage.

PubMed Disclaimer

LinkOut - more resources