Venous oxygen measurements in the inferior vena cava in neonates with respiratory failure

Affiliations

Venous oxygen measurements in the inferior vena cava in neonates with respiratory failure

FB Plötz et al. Crit Care. 1998.

Abstract

BACKGROUND: The present study was undertaken to examine the feasibility of venous oxygen measurements in the inferior vena cava (IVC) via a catheter through the umbilical vein. This may serve as a proxy for mixed venous oxygenation and the complications of right atrial cannulation can be avoided at the same time. It has the added advantage of not being affected by atrial right-left shunting. RESULTS: The study included 22 neonates requiring mechanical ventilation for respiratory insufficiency. The success rate of catheterization of the IVC via the umbilical vein was 81% and there was no catheter-related complications. Fifty paired blood samples were obtained and analyzed while the patients were hemodynamically stable. Linear regression analysis showed a poor correlation between arterial oxygen tension (PaO2) and the arterial-venous oxygen content difference [C(a-v)O2], r = -0.005, and between PaO2 and the fractional oxygen extraction (FOE), r = -0.114. There was also a poor correlation between arterial oxygen saturation (SaO2) and C(a-v)O2, r = -0.057, and between SaO2 and FOE, r =-0.139. The correlations between venous oxygen tension (PvO2) and C(a-v)O2 and between PvO2 and FOE were r = -0.528 and r = 0.592, respectively. There were good correlations between various oxygen saturation (SvO2) and C(a-v)O2, r = -0.634, and between SvO2 FOE, r = -0.712. CONCLUSION: Venous oxygen measurement in the IVC via an umbilical vein catheter is a simple and safe procedure and provides information about the tissue oxygenation status of critically ill neonates.

PubMed Disclaimer

Figures

Figure 1
Figure 1
(a) A poor correlation (r = -0.139) was observed between arterial oxygen saturation and the oxygen extraction ratio and (b) a good correlation (r = -0.712) was observed between venous oxygen saturation and the oxygen extraction ratio.

Similar articles

Cited by

References

    1. Whyte RK. Mixed venous oxygen saturation in the newborn. Can we and should we measure it? Scand J Clin Lab Invest. 1990;50:203–211. - PubMed
    1. O'Connor TA, Hall RT. Mixed venous oxygenatio in critically ill neonates. Crit Care Med. 1994;22:343–346. - PubMed
    1. Dudell G, Cornish JD, Barlett RH. What constitutes adequate oxygenation. Pediatrics. 1990;85:39–41. - PubMed
    1. Van der Hoeven MAHBM, Maertzdorf WJ, Blanco CE. Feasibility and accuracy of a fiberoptic catheter for measurement of venous oxygen saturation in newborn infants. Acta Paediatr. 1995;84:122–127. - PubMed
    1. Hirschl RB, Palmer P, Heiss KF, Hultquist K, Fazzalari F, Bartlett RH. Evaluation of the right atrial venous oxygen saturation as a physiologic monitor in a neonatal model. J Pediatr Surg. 1993;28:901–905. - PubMed

LinkOut - more resources