Determination of dioxins/furans and PCBs by quadrupole ion-trap gas chromatography-mass spectrometry
- PMID: 11079247
- DOI: 10.1002/1098-2787(2000)19:5<305::AID-MAS4>3.0.CO;2-T
Determination of dioxins/furans and PCBs by quadrupole ion-trap gas chromatography-mass spectrometry
Abstract
The versatility and sensitivity of the quadrupole ion trap tandem mass spectrometer has been applied to the determination of polychlorodibenzo-p-dioxins (PCDDs) and polychlorodibenzofurans (PCDFs), and of polychlorinated biphenyls (PCBs). A brief introduction to the theory of ion confinement in a quadrupole ion trap permits discussion of ion trajectory stability, mass-selective ion ejection, the frequencies of ion motion, and the role of resonant excitation of ion motion. The tandem mass spectrometric examination of PCDDs and PCDFs eluting and co-eluting from a gas chromatographic column is described. Illustrative examples are given of the analysis of field samples containing PCDDs and PCDFs. A comparison is presented of the performance of each of a quadrupole ion trap tandem mass spectrometer, a triple stage quadrupole mass spectrometer, and a sector instrument of relatively high mass resolution for the determination of PCDDs and PCDFs. This comparison is made with respect to instrument tuning, calibration plots, detection limits, ion signals at low concentration, relative response factors, ionization cross-sections, and the examination of field samples. The application of quadrupole ion trap tandem mass spectrometry to the examination of PCBs is focused upon those PCB congeners that have the greatest toxicity. 39 congeners of the total of 209 PCB congeners have been identified as having the greatest toxicities. Chemical ionization has been used for the determination of co-eluting congeners #77 and #110 where the toxicity of the former is much greater than that of the latter. An analytical protocol, based on the variation of molecular ion fragmentation according to the degree (or absence) of chlorine ortho-substitution, has been proposed for distinguishing between toxic and nontoxic PCB congeners.
Similar articles
-
Separation of polychlorinated dibenzo-p-dioxins/furans, non-ortho/mono/di/tri/tetra-ortho-polychlorinated biphenyls, and polybrominated diphenyl ethers groups of compounds prior to their determination with large volume injection gas chromatography-Quadrupole ion storage tandem mass spectrometry.Anal Chim Acta. 2013 Oct 17;799:88-98. doi: 10.1016/j.aca.2013.08.053. Epub 2013 Sep 10. Anal Chim Acta. 2013. PMID: 24091378
-
Meeting the European Commission performance criteria for the use of triple quadrupole GC-MS/MS as a confirmatory method for PCDD/Fs and dl-PCBs in food and feed samples.Anal Bioanal Chem. 2016 May;408(13):3511-25. doi: 10.1007/s00216-016-9428-9. Epub 2016 Feb 27. Anal Bioanal Chem. 2016. PMID: 26922340
-
Developing an Improved Strategy for the Analysis of Polychlorinated Dibenzo-p-Dioxins/Furans and Dioxin-like Polychlorinated Biphenyls in Contaminated Soils Using a Combination of a One-Step Cleanup Method and Gas Chromatography with Triple Quadrupole Mass Spectrometry.Toxics. 2023 Aug 28;11(9):738. doi: 10.3390/toxics11090738. Toxics. 2023. PMID: 37755748 Free PMC article.
-
Determination of polychlorinated dibenzo-p-dioxins, dibenzofurans, and biphenyls by gas chromatography/mass spectrometry in the negative chemical ionization mode with different reagent gases.Mass Spectrom Rev. 2002 Nov-Dec;21(6):373-87. doi: 10.1002/mas.10037. Mass Spectrom Rev. 2002. PMID: 12666147 Review.
-
The toxicokinetics and metabolism of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) and their relevance for toxicity.Crit Rev Toxicol. 1994;24(1):1-74. doi: 10.3109/10408449409017919. Crit Rev Toxicol. 1994. PMID: 8172651 Review.
Cited by
-
Generation by a widely applicable approach of a hybrid dioxygenase showing improved oxidation of polychlorobiphenyls.Appl Environ Microbiol. 2007 Apr;73(8):2682-9. doi: 10.1128/AEM.02523-06. Epub 2007 Feb 23. Appl Environ Microbiol. 2007. PMID: 17322323 Free PMC article.
-
Semi-Empirical Topological Method for Prediction of the Relative Retention Time of Polychlorinated Biphenyl Congeners on 18 Different HR GC Columns.Chromatographia. 2010 Sep;72(5-6):523-533. doi: 10.1365/s10337-010-1696-5. Epub 2010 Aug 10. Chromatographia. 2010. PMID: 20835381 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources