Glucoweb: a case study of secure, remote biomonitoring and communication
- PMID: 11079956
- PMCID: PMC2243912
Glucoweb: a case study of secure, remote biomonitoring and communication
Abstract
As the Internet begins to play a greater role in many healthcare processes, it is inevitable that remote monitoring of patients' physiological parameters over the Internet will become increasingly commonplace. Internet-based communication between patients and their healthcare providers has already become prevalent, and has gained significant attention in terms of confidentiality issues. However, transmission of data directly from patients' physiological biomonitoring devices over the Web has garnered significantly less focus, especially in the area of authentication and security. In this paper, we describe a prototype system called Glucoweb, which allows patients with diabetes mellitus to transmit their self-monitored blood glucose data directly from their personal glucometer device to their diabetes care provider over the Internet. No customized software is necessary on the patient's computer, only a Web browser and active Internet connection. We use this example to highlight key authentication and security measures that should be considered for devices that transmit healthcare data to remote locations.
Similar articles
-
Applications of Multi-Channel Safety Authentication Protocols in Wireless Networks.J Med Syst. 2016 Jan;40(1):26. doi: 10.1007/s10916-015-0360-x. Epub 2015 Nov 7. J Med Syst. 2016. PMID: 26547846
-
A remote data access architecture for home-monitoring health-care applications.Med Eng Phys. 2007 Mar;29(2):199-204. doi: 10.1016/j.medengphy.2006.03.002. Epub 2006 Apr 18. Med Eng Phys. 2007. PMID: 16621655
-
Remote health monitoring using mobile phones and Web services.Telemed J E Health. 2010 Jun;16(5):603-7. doi: 10.1089/tmj.2009.0165. Telemed J E Health. 2010. PMID: 20575728
-
Patient confidentiality, data security, and provider liabilities in diabetes management.Diabetes Technol Ther. 2003;5(4):631-40. doi: 10.1089/152091503322250659. Diabetes Technol Ther. 2003. PMID: 14511418 Review.
-
Research use of the AIDA www.2aida.org diabetes software simulation program: a review--part 2. Generating simulated blood glucose data for prototype validation.Diabetes Technol Ther. 2003;5(4):641-51. doi: 10.1089/152091503322250668. Diabetes Technol Ther. 2003. PMID: 14511419 Review.
Cited by
-
How continuous monitoring changes the interaction of patients with a mobile telemedicine system.J Diabetes Sci Technol. 2011 Jan 1;5(1):5-12. doi: 10.1177/193229681100500102. J Diabetes Sci Technol. 2011. PMID: 21303619 Free PMC article. Clinical Trial.
References
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials