Spectra of cells in flow cytometry using a vidicon detector
- PMID: 110874
- DOI: 10.1177/27.6.110874
Spectra of cells in flow cytometry using a vidicon detector
Abstract
A TV type vidicon detector was interfaced to a flow cytometer (FCM) to obtain spectra of fluorophores in cells during flow. The normal operations of the FCM are undisturbed. A spectrograph spreads 320 nm of the fluorophore fluorescence emission across the 500 channels of the detector. Spectra of fluorescamine (a surface labeling agent) and of propidium iodide (a nuclear stain) were obtained from Balb 3T3 cells, and the chlorophyll and phycobilin peaks were resolved from flowing blue-green algae in the FCM. Under typical flow conditions, operation of the vidicon in the continuous mode gives for these fluorophores a S/N of several hundred to one in approximately 3 sec. The vidicon was also gated to obtain spectra of single cells and of cells in selected portions of the cell cycle. For example, the spectrum of fluorescamine was obtained from cells in the G1 phase of the growth cycle by using as a gate trigger the FCM discriminator output derived from the propidium iodide signal.
Similar articles
-
Quantitative determination of transformed cells in a mixed population by stimultaneous fluorescence analysis of cell surface and DNA an individual cells.Proc Natl Acad Sci U S A. 1977 Apr;74(4):1626-30. doi: 10.1073/pnas.74.4.1626. Proc Natl Acad Sci U S A. 1977. PMID: 193110 Free PMC article.
-
Analysis of phytoplankton by flow cytometry.Cytometry. 1982 Jan;2(4):258-64. doi: 10.1002/cyto.990020410. Cytometry. 1982. PMID: 6799265
-
Extended application of flow microfluorometry by means of dual laser excitation.Histochemistry. 1977 Apr 4;51(4):305-13. doi: 10.1007/BF00494366. Histochemistry. 1977. PMID: 870462
-
Sequestration of mitotic (M-phase) chromosomes in autophagosomes: mitotic programmed cell death in human Chang liver cells induced by an OH* burst from vanadyl(4).Anat Rec. 1996 May;245(1):1-8. doi: 10.1002/(SICI)1097-0185(199605)245:1<1::AID-AR1>3.0.CO;2-2. Anat Rec. 1996. PMID: 8731032
-
[Cancer chemo-endocrine therapy and its cell biological basis].Hum Cell. 1998 Sep;11(3):109-14. Hum Cell. 1998. PMID: 10086273 Review. Japanese.
Cited by
-
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition).Eur J Immunol. 2019 Oct;49(10):1457-1973. doi: 10.1002/eji.201970107. Eur J Immunol. 2019. PMID: 31633216 Free PMC article.
-
Visible and near infrared fluorescence spectral flow cytometry.Cytometry A. 2013 Mar;83(3):253-64. doi: 10.1002/cyto.a.22241. Epub 2012 Dec 6. Cytometry A. 2013. PMID: 23225549 Free PMC article.
-
Prism Design for Spectral Flow Cytometry.Micromachines (Basel). 2023 Jan 26;14(2):315. doi: 10.3390/mi14020315. Micromachines (Basel). 2023. PMID: 36838016 Free PMC article.
-
High Throughput Multi-Omics Approaches for Clinical Trial Evaluation and Drug Discovery.Front Immunol. 2021 Mar 31;12:590742. doi: 10.3389/fimmu.2021.590742. eCollection 2021. Front Immunol. 2021. PMID: 33868223 Free PMC article. Review.
-
Microfluidic flow cytometer for quantifying photobleaching of fluorescent proteins in cells.Anal Chem. 2012 May 1;84(9):3929-37. doi: 10.1021/ac202825z. Epub 2012 Apr 9. Anal Chem. 2012. PMID: 22424298 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources