Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2000 Sep;26(9):1252-8.
doi: 10.1007/s001340000601.

Evaluation of noninvasive determinants for capillary leakage syndrome in septic shock patients

Affiliations

Evaluation of noninvasive determinants for capillary leakage syndrome in septic shock patients

G Marx et al. Intensive Care Med. 2000 Sep.

Abstract

Objective: Capillary leakage syndrome (CLS) is a frequent complication in sepsis, characterized by loss of intravasal fluids leading to generalized edema and hemodynamic instability despite massive fluid therapy. In spite of its importance no standardized diagnostic criteria are available for CLS.

Design: Prospective clinical study.

Setting: 1,800-bed university hospital

Patients: Six septic shock patients with CLS were compared to six control patients.

Measurements and results: CLS was clinically determined by generalized edema, positive fluid balance, and weight gain. Plasma volume was measured by indocyanine green, red blood cell volume by chromium-51 labeled erythrocytes, and colloid osmotic pressure before and 90 min after the administration of 300 ml 20% albumin. Extracellular water (ECW) was measured using the inulin distribution volume and bioelectrical impedance analysis. Red blood cells averaged 20.2 +/- 1.0 ml/ kg body weight in CLS patients and 23.3 +/- 4.1 in controls. ECW was higher in CLS patients than in controls (40.0 +/- 6.9 vs. 21.7 +/- 3.71; p< 0.05). ECW of inulin was correlated with that measured by bioelectrical impedance analysis (r = 0.74, p< 0.01). The increase in colloid osmotic pressure over the 90 min was less in CLS patients than in controls (1.1 +/- 0.3 vs. 2.8 +/- 1.3 mmHg;p< 0.05).

Conclusion: These results suggest that measurements of an increased ECW using bioelectrical impedance analysis combined with a different response of colloid osmotic pressure to administration of albumin can discriminate noninvasively between patients with and those without CLS.

PubMed Disclaimer

Publication types

LinkOut - more resources