Measuring tumor blood flow with H(2)(15)O: practical considerations
- PMID: 11091110
- DOI: 10.1016/s0969-8051(00)00136-0
Measuring tumor blood flow with H(2)(15)O: practical considerations
Abstract
The ability to measure blood flow to tumors non-invasively may be of importance in monitoring tumor therapies, assessing drug delivery, and understanding tumor physiology. Of all the radiotracer methods that have been proposed to measure tumor blood flow, the method based on labeled water-H(2)(15)O-may be the most applicable to tumors. It is highly diffusible, does not participate significantly in metabolic processes during the short times involved in the study, and its uptake and clearance can be easily modeled. We present here an analysis of the bolus injection water methodology and how it might best be used to monitor tumor blood flow. Several different formulations of the basic methodology, based on previous applications in the heart and brain, are discussed. Potential problems of adapting these previous methodologies to tumor blood flow are presented.
Similar articles
-
Assessment of hepatic blood flow by PET with 15O water: correlation between per-rectal portal scintigraphy with 99Tc(m)-pertechnetate and scintigraphy with 99Tc(m)-GSA.Nucl Med Commun. 2000 Jun;21(6):533-8. doi: 10.1097/00006231-200006000-00006. Nucl Med Commun. 2000. PMID: 10894562
-
[Tumor blood flow measured by dynamic CT].Nihon Igaku Hoshasen Gakkai Zasshi. 1994 Mar 25;54(4):253-7. Nihon Igaku Hoshasen Gakkai Zasshi. 1994. PMID: 8177699 Japanese.
-
Myocardial blood flow: comparison of oxygen-15-water bolus injection, slow infusion and oxygen-15-carbon dioxide slow inhalation.J Nucl Med. 1995 Jan;36(1):78-85. J Nucl Med. 1995. PMID: 7799088
-
Clinical applications of myocardial perfusion assessments made with oxygen-15 water and positron emission tomography.Cardiology. 1997 Jan-Feb;88(1):71-9. doi: 10.1159/000177313. Cardiology. 1997. PMID: 8960629 Review.
-
[Noninvasive quantitative evaluation of regional myocardial blood flow and tissue fraction with O-15-labeled water and carbon dioxide inhalation using dynamic positron emission tomography].Nihon Rinsho. 1994 Jul;52 Suppl(Pt 1):614-21. Nihon Rinsho. 1994. PMID: 12436591 Review. Japanese. No abstract available.
Cited by
-
Metabolic-flow relationships in primary breast cancer: feasibility of combined PET/dynamic contrast-enhanced CT.Eur J Nucl Med Mol Imaging. 2009 Mar;36(3):416-21. doi: 10.1007/s00259-008-0948-1. Epub 2008 Sep 26. Eur J Nucl Med Mol Imaging. 2009. PMID: 18818917
-
Evaluation of basis function and linear least squares methods for generating parametric blood flow images using 15O-water and Positron Emission Tomography.Mol Imaging Biol. 2005 Jul-Aug;7(4):273-85. doi: 10.1007/s11307-005-0007-2. Mol Imaging Biol. 2005. PMID: 16080023
-
Imaging angiogenesis of genitourinary tumors.Nat Rev Urol. 2010 Feb;7(2):69-82. doi: 10.1038/nrurol.2009.262. Epub 2010 Jan 19. Nat Rev Urol. 2010. PMID: 20084077 Review.
-
Pharmacodynamic analysis of magnetic resonance imaging-monitored focused ultrasound-induced blood-brain barrier opening for drug delivery to brain tumors.Biomed Res Int. 2013;2013:627496. doi: 10.1155/2013/627496. Epub 2013 Mar 31. Biomed Res Int. 2013. PMID: 23607093 Free PMC article.
-
Noninvasive diffuse optical monitoring of head and neck tumor blood flow and oxygenation during radiation delivery.Biomed Opt Express. 2012 Feb 1;3(2):259-72. doi: 10.1364/BOE.3.000259. Epub 2012 Jan 4. Biomed Opt Express. 2012. PMID: 22312579 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources