Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2000 Nov 15;36(6):1749-66.
doi: 10.1016/s0735-1097(00)00962-1.

Measurement, interpretation and clinical potential of QT dispersion

Affiliations
Free article
Review

Measurement, interpretation and clinical potential of QT dispersion

M Malik et al. J Am Coll Cardiol. .
Free article

Abstract

QT dispersion was originally proposed to measure spatial dispersion of ventricular recovery times. Later, it was shown that QT dispersion does not directly reflect the dispersion of recovery times and that it results mainly from variations in the T loop morphology and the error of QT measurement. The reliability of both automatic and manual measurement of QT dispersion is low and significantly lower than that of the QT interval. The measurement error is of the order of the differences between different patient groups. The agreement between automatic and manual measurement is poor. There is little to choose between various QT dispersion indices, as well as between different lead systems for their measurement. Reported values of QT dispersion vary widely, e.g., normal values from 10 to 71 ms. Although QT dispersion is increased in cardiac patients compared with healthy subjects and prognostic value of QT dispersion has been reported, values are largely overlapping, both between healthy subjects and cardiac patients and between patients with and without adverse outcome. In reality, QT dispersion is a crude and approximate measure of abnormality of the complete course of repolarization. Probably only grossly abnormal values (e.g. > or =100 ms), outside the range of measurement error may potentially have practical value by pointing to a grossly abnormal repolarization. Efforts should be directed toward established as well as new methods for assessment and quantification of repolarization abnormalities, such as principal component analysis of the T wave, T loop descriptors, and T wave morphology and wavefront direction descriptors.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources