Respiratory efficacy of subglottic low-frequency, subglottic combined-frequency, and supraglottic combined-frequency jet ventilation during microlaryngeal surgery
- PMID: 11094009
- DOI: 10.1097/00000539-200012000-00039
Respiratory efficacy of subglottic low-frequency, subglottic combined-frequency, and supraglottic combined-frequency jet ventilation during microlaryngeal surgery
Abstract
We tested the respiratory efficacy of different jet ventilation techniques (subglottic low-frequency versus subglottic combined-frequency and subglottic combined-frequency versus supraglottic combined frequency) in patients undergoing microlaryngeal surgery. The PaCO(2) and the quotient of arterial oxygen tension (PaO(2)) over FIO(2) were measured. After anesthetic induction (propofol, remifentanil, vecuronium), an endotracheal Mon-Jet catheter (Xomed, Jacksonville, FL) for subglottic jet ventilation and a laryngoscope for supraglottic jet ventilation (Carl Reiner G.m.b.H., Vienna, Austria) were inserted. In Group 1 (n = 18), subglottic low-frequency (15 breaths/min), combined-frequency (600 and 15 breaths/min), and low-frequency jet ventilation was subsequently performed (15 min each). In Group 2 (n = 19), the sequence was supraglottic, subglottic, and supraglottic combined-frequency jet ventilation. The driving pressures were initially adjusted to achieve normocapnia and were not changed during the entire study period. The FIO(2) was measured endotracheally. The Wilcoxon's signed rank test was applied. In Group 1, PaCO(2) and PaO(2)/FIO(2) improved significantly after switching from subglottic low-frequency to subglottic combined-frequency jet ventilation (PaCO(2), from 46.6 +/-8.3 to 42.1+/-8.1 mm Hg; PaO(2)/FIO(2), from 311+/-144 to 361+/-141 mm Hg; P<0.05). In Group 2, PaCO(2) increased and PaO(2)/FIO(2) decreased significantly after switching from supraglottic to subglottic combined-frequency jet ventilation (PaCO(2), from 39.4+/-7.1 to 45.9+/-7.5 mm Hg; PaO(2)/FIO(2), from 415+/-114 to 351+/-129 mm Hg; P<0.05). We conclude that subglottic combined-frequency jet ventilation is less effective than supraglottic combined-frequency ventilation, but more effective than subglottic low-frequency jet ventilation.
Implications: The combination of high and low respiratory frequencies (600 and 15 breaths/min) improves pulmonary gas exchange during subglottic jet ventilation via an endotracheal catheter. However, subglottic combined-frequency jet ventilation is less effective than supraglottic combined-frequency jet ventilation via a jet ventilation laryngoscope.
Comment in
-
What to prefer during jet ventilation for endolaryngeal procedures, risk of barotrauma or of aspiration of contaminating material?Anesth Analg. 2001 Dec;93(6):1625. doi: 10.1097/00000539-200112000-00069. Anesth Analg. 2001. PMID: 11726463 No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical