Mechanical effects of heat-moisture exchangers in ventilated patients
- PMID: 11094485
- PMCID: PMC137236
- DOI: 10.1186/cc361
Mechanical effects of heat-moisture exchangers in ventilated patients
Abstract
Although they represent a valuable alternative to heated humidifiers, artificial noses have unfavourable mechanical effects. Most important of these is the increase in dead space, with consequent increase in the ventilation requirement. Also, artificial noses increase the inspiratory and expiratory resistance of the apparatus, and may mildly increase intrinsic positive end-expiratory pressure. The significance of these effects depends on the design and function of the artificial nose. The pure humidifying function results in just a moderate increase in dead space and resistance of the apparatus, whereas the combination of a filtering function with the humidifying function may critically increase the volume and the resistance of the artificial nose, especially when a mechanical filter is used. The increase in the inspiratory load of ventilation that is imposed by artificial noses, which is particularly significant for the combined heat-moisture exchanger filters, should be compensated for by an increase either in ventilator output or in patient's work of breathing. Although both approaches can be tolerated by most patients, some exceptions should be considered. The increased pressure and volume that are required to compensate for the artificial nose application increase the risk of barotrauma and volutrauma in those patients who have the most severe alterations in respiratory mechanics. Moreover, those patients who have very limited respiratory reserve may not be able to compensate for the inspiratory work imposed by an artificial nose. When we choose an artificial nose, we should take into account the volume and resistance of the available devices. We should also consider the mechanical effects of the artificial noses when setting mechanical ventilation and when assessing a patient's ability to breathe spontaneously.
Similar articles
-
Unfavorable mechanical effects of heat and moisture exchangers in ventilated patients.Intensive Care Med. 1997 Apr;23(4):399-405. doi: 10.1007/s001340050347. Intensive Care Med. 1997. PMID: 9142578 Clinical Trial.
-
The effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients.Respir Care. 2000 Mar;45(3):306-12. Respir Care. 2000. PMID: 10771799 Clinical Trial.
-
Mechanical effects of airway humidification devices in difficult to wean patients.Crit Care Med. 2003 May;31(5):1306-11. doi: 10.1097/01.CCM.0000063284.92122.0E. Crit Care Med. 2003. PMID: 12771595 Clinical Trial.
-
Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 2 - practical use, including problems, and their use with paediatric patients.Anaesthesia. 2011 Jan;66(1):40-51. doi: 10.1111/j.1365-2044.2010.06564.x. Epub 2010 Nov 30. Anaesthesia. 2011. PMID: 21118189 Review.
-
Measurement of air trapping, intrinsic positive end-expiratory pressure, and dynamic hyperinflation in mechanically ventilated patients.Respir Care. 2005 Jan;50(1):110-23; discussion 123-4. Respir Care. 2005. PMID: 15636649 Review.
Cited by
-
Effect of IFN-α and other commonly used nebulization drugs in different nebulization methods on the resistance of breathing circuit filters under invasive mechanical ventilation.Ann Transl Med. 2022 Feb;10(4):189. doi: 10.21037/atm-22-84. Ann Transl Med. 2022. PMID: 35280392 Free PMC article.
-
Heat and Moisture Exchanger Occlusion Leading to Sudden Increased Airway Pressure: A Case Report Using ChatGPT as a Personal Writing Assistant.Cureus. 2023 Apr 8;15(4):e37306. doi: 10.7759/cureus.37306. eCollection 2023 Apr. Cureus. 2023. PMID: 37168205 Free PMC article.
-
Comparison of the effects of two humidifier systems on endotracheal tube resistance.Intensive Care Med. 2011 Nov;37(11):1773-9. doi: 10.1007/s00134-011-2351-9. Epub 2011 Sep 27. Intensive Care Med. 2011. PMID: 21946924
-
Effect of humidifying devices on the measurement of tidal volume by mechanical ventilators.J Anesth. 2006;20(3):166-72. doi: 10.1007/s00540-006-0390-0. J Anesth. 2006. PMID: 16897234 Clinical Trial.
-
Humidification during mechanical ventilation in the adult patient.Biomed Res Int. 2014;2014:715434. doi: 10.1155/2014/715434. Epub 2014 Jun 25. Biomed Res Int. 2014. PMID: 25089275 Free PMC article. Review.
References
-
- Shelly MP, Lloyd GM, Park GR. A review of the mechanisms and methods of humidification of inspired gases. Intens Care Med. 1988;14:1–9. - PubMed
-
- Hedley RM, Allt-Graham J. Heat and moisture exchangers and breathing filters. Br J Anaesth. 1994;73:227–236. - PubMed
-
- Martin C, Perrin G, Gevaudan MJ, Saux P, Gouin F. Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit. . Chest. 1990;97:144–149. - PubMed
-
- Misset B, Escudier B, Rivara D, Leclercq B, Nitemberg G. Heat and moisture exchangers vs heated humidifiers during long-term mechanical ventilation: a prospective randomized study. Chest. 1991;100:160–163. - PubMed
-
- Boots RJ, Howe S, George N, Harris FM, Faoagali J. Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients. Crit Care Med. 1997;25:1707–1712. - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources