An electrically calibrated plethysmograph for direct measurement of limb blood flow
- PMID: 1110089
- DOI: 10.1109/tbme.1975.324535
An electrically calibrated plethysmograph for direct measurement of limb blood flow
Similar articles
-
Comparison of an impedance device to a displacement plethysmograph for study of finger blood flow.Aviat Space Environ Med. 1976 Jan;47(1):33-8. Aviat Space Environ Med. 1976. PMID: 1247433
-
Impedance plethysmography: evaluation of a simplified system of electrodes for the measurement of blood flow in the lower limb.Br J Surg. 1976 May;63(5):413-6. doi: 10.1002/bjs.1800630520. Br J Surg. 1976. PMID: 1268485
-
Digital pulse plethysmography and digital blood pressure measurement in the evaluation of arterial circulation in the lower limb.Scand J Clin Lab Invest Suppl. 1973;128:117-21. Scand J Clin Lab Invest Suppl. 1973. PMID: 4764568 No abstract available.
-
Noninvasive blood flow measurement.Crit Rev Biomed Eng. 1985;12(3):201-35. Crit Rev Biomed Eng. 1985. PMID: 3158479 Review.
-
Instrumental methods in the study of vascular disease.Am Heart J. 1980 Apr;99(4):517-27. doi: 10.1016/0002-8703(80)90389-0. Am Heart J. 1980. PMID: 6987856 Review. No abstract available.
Cited by
-
Quantitative aspects of the inhibition by N(G)-monomethyl-L-arginine of responses to endothelium-dependent vasodilators in human forearm vasculature.Br J Pharmacol. 2001 Nov;134(5):939-44. doi: 10.1038/sj.bjp.0704338. Br J Pharmacol. 2001. PMID: 11682440 Free PMC article. Clinical Trial.
-
Altered venous capacitance as a cause of postprandial hypotension in multiple system atrophy.Clin Auton Res. 2007 Feb;17(1):20-5. doi: 10.1007/s10286-006-0378-8. Epub 2006 Nov 29. Clin Auton Res. 2007. PMID: 17139443
-
SPECT/CT-plethysmography--non-invasive quantitation of bone and soft tissue blood flow.J Orthop Surg Res. 2008 Aug 18;3:36. doi: 10.1186/1749-799X-3-36. J Orthop Surg Res. 2008. PMID: 18710528 Free PMC article.
-
How reproducible is bilateral forearm plethysmography?Br J Clin Pharmacol. 1998 Feb;45(2):131-9. doi: 10.1046/j.1365-2125.1998.00656.x. Br J Clin Pharmacol. 1998. PMID: 9491825 Free PMC article. Clinical Trial.
-
Sympathetic activation increases NO release from eNOS but neither eNOS nor nNOS play an essential role in exercise hyperemia in the human forearm.Am J Physiol Heart Circ Physiol. 2013 May;304(9):H1225-30. doi: 10.1152/ajpheart.00783.2012. Epub 2013 Feb 22. Am J Physiol Heart Circ Physiol. 2013. PMID: 23436331 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources