Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2000 Dec 4;56(6 Suppl 1):87-91.
doi: 10.1016/s0090-4295(00)00597-5.

Long-term results of a multicenter study on sacral nerve stimulation for treatment of urinary urge incontinence, urgency-frequency, and retention

Affiliations
Clinical Trial

Long-term results of a multicenter study on sacral nerve stimulation for treatment of urinary urge incontinence, urgency-frequency, and retention

S W Siegel et al. Urology. .

Abstract

Many patients have chronic, debilitating symptoms of voiding dysfunction that are refractory to conventional medical or surgical therapies. This multicenter, prospective study evaluated the long-term effectiveness of sacral nerve stimulation using the implantable Medtronic InterStim therapy for urinary control in patients with otherwise intractable complaints of urinary urge incontinence, urgency-frequency, or retention. Each patient first underwent temporary, percutaneous sacral nerve test stimulation. If at least a 50% reduction in target symptoms was documented for at least 3 days, patients received a permanent Medtronic InterStim sacral nerve stimulation system that includes a surgically implanted lead and neurostimulator. Regular follow-up was conducted with outcome data. We report here on patients who have been observed from 1.5 to 3 years postimplantation. The results demonstrate that after 3 years, 59% of 41 urinary urge incontinent patients showed greater than 50% reduction in leaking episodes per day with 46% of patients being completely dry. After 2 years, 56% of the urgency-frequency patients showed greater than 50% reduction in voids per day. After 1. 5 years, 70% of 42 retention patients showed greater than 50% reduction in catheter volume per catheterization. We conclude that the Medtronic InterStim therapy for urinary control system is an effective therapy with sustained clinical benefit for patients with intractable symptoms of urinary urge incontinence, urgency-frequency, or retention.

PubMed Disclaimer

Publication types

LinkOut - more resources