Data explosion: the challenge of multidetector-row CT
- PMID: 11116170
- DOI: 10.1016/s0720-048x(00)00270-9
Data explosion: the challenge of multidetector-row CT
Abstract
The development of multi detector-row CT has brought many exciting advancements to clinical CT scanning. While multi detector-row CT offers unparalleled speed of acquisition, spatial resolution, and anatomic coverage, a challenge presented by these advantages is the substantial increase on the number of reconstructed cross-sections that are rapidly created and in need of analysis. This manuscript discusses currently available alternative visualization tecvhniques for the assessment of volumetric data acquired with multi detector-row CT. Although the current capabilities of 3-D workstations offer many possibilities for alternative analysis of MCDT data, substantial improvements both in automated processing, processing speed and user interface will be necessary to realize the vision of replacing the primary analysis of transverse reconstruction's with alternative analyses. The direction that some of these future developments might take are discussed.
Similar articles
-
3-D imaging with MDCT.Eur J Radiol. 2003 Mar;45 Suppl 1:S37-41. doi: 10.1016/s0720-048x(03)00035-4. Eur J Radiol. 2003. PMID: 12598025 Review.
-
Multidetector-row spiral computed tomography in the diagnosis of thoracic diseases.Respir Care. 2001 Sep;46(9):912-21. Respir Care. 2001. PMID: 11513764 Review.
-
Multi-detector-row CT angiography of peripheral arteries.Semin Ultrasound CT MR. 2003 Aug;24(4):268-79. doi: 10.1016/s0887-2171(03)90016-3. Semin Ultrasound CT MR. 2003. PMID: 12954008 Review.
-
Multi-detector row CT: principles and practice for abdominal applications.Radiology. 2004 Nov;233(2):323-7. doi: 10.1148/radiol.2332030994. Epub 2004 Sep 30. Radiology. 2004. PMID: 15459326
-
Multi-detector row CT of mesenteric ischemia: can it be done?Radiographics. 2001 Nov-Dec;21(6):1463-73. doi: 10.1148/radiographics.21.6.g01nv091463. Radiographics. 2001. PMID: 11706217 Review.
Cited by
-
Visual Interpretation with Three-Dimensional Annotations (VITA): three-dimensional image interpretation tool for radiological reporting.J Digit Imaging. 2014 Feb;27(1):49-57. doi: 10.1007/s10278-013-9624-5. J Digit Imaging. 2014. PMID: 23979113 Free PMC article.
-
On combining image-based and ontological semantic dissimilarities for medical image retrieval applications.Med Image Anal. 2014 Oct;18(7):1082-100. doi: 10.1016/j.media.2014.06.009. Epub 2014 Jul 2. Med Image Anal. 2014. PMID: 25036769 Free PMC article.
-
On-the-fly generation of multiplanar reformation images independent of CT scanner type.J Digit Imaging. 2008 Sep;21(3):306-11. doi: 10.1007/s10278-007-9032-9. Epub 2007 Mar 24. J Digit Imaging. 2008. PMID: 17384976 Free PMC article.
-
Multidetector-row CT angiographic imaging of the celiac trunk: anatomy and normal variants.Surg Radiol Anat. 2008 Jun;30(4):303-10. doi: 10.1007/s00276-008-0324-7. Epub 2008 Feb 20. Surg Radiol Anat. 2008. PMID: 18286222
-
Multipath Curved Planar Reformations of Peripheral CT Angiography: Diagnostic Accuracy and Time Efficiency.Cardiovasc Intervent Radiol. 2018 May;41(5):718-725. doi: 10.1007/s00270-017-1846-3. Epub 2017 Dec 7. Cardiovasc Intervent Radiol. 2018. PMID: 29218656 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical