Laryngoscope handles: a potential for infection
- PMID: 11132011
Laryngoscope handles: a potential for infection
Abstract
Laryngoscope handles do not usually come in direct contact with the patient's mucous membranes. Consequently, routine disinfection of laryngoscope handles is not currently standard practice unless gross contamination is clearly evident. Recent reports indicate that apparently clean handles may be contaminated with blood or body fluids. No report examined microbes on handles. The present article describes the incidence and types of microbes on laryngoscope handles after their use in the operating rooms of a 502-bed medical center in northwestern Pennsylvania. Twenty laryngoscope handles were cultured on Mueller Hinton 5% sheep blood agar plates. The plates were incubated at 37 degrees C for 48 hours and examined for growth. The identification, incidence, and susceptibility patterns of organisms were determined. Microorganisms were present on all 20 laryngoscope handles. Nine different types were isolated; some strains were resistant to multiple antibiotics. Organisms were categorized as contaminants or opportunistic pathogens. The presence of opportunistic pathogens places anesthesia providers and patients at risk of nosocomial infections. Based on the recommendations of the 1997 American Association of Nurse Anesthetists' Infection Control Guide and the results of the present study, institutional guidelines should be established for the use of disposable laryngoscope covers, high-level (destroying all microorganisms with the exception of high numbers of bacterial spores) disinfection, or sterilization of laryngoscope equipment between each patient use.
Similar articles
-
Contamination of laryngoscope handles.J Hosp Infect. 2010 Feb;74(2):123-8. doi: 10.1016/j.jhin.2009.09.015. Epub 2010 Jan 22. J Hosp Infect. 2010. PMID: 20096953
-
Incidence of visible and occult blood on laryngoscope blades and handles.AANA J. 1997 Jun;65(3):241-6. AANA J. 1997. PMID: 9233093
-
Prevention of disease transmission during flexible laryngoscopy.Am J Infect Control. 2007 Oct;35(8):536-44. doi: 10.1016/j.ajic.2006.09.010. Am J Infect Control. 2007. PMID: 17936146 Review.
-
Infection control practices of laryngoscope blades: a review of the literature.AANA J. 2012 Aug;80(4):274-8. AANA J. 2012. PMID: 23251996 Review.
-
Contamination and Disinfection of Rigid Laryngoscopes: A Literature Review.AORN J. 2019 Jul;110(1):49-59. doi: 10.1002/aorn.12724. AORN J. 2019. PMID: 31246299 Review.
Cited by
-
Disinfection of laryngoscopes: A survey of practice.Indian J Anaesth. 2017 Mar;61(3):245-249. doi: 10.4103/ija.IJA_347_16. Indian J Anaesth. 2017. PMID: 28405039 Free PMC article.
-
Comparison of efficacy and cost-effectiveness of 0.55% ortho-phthalaldehyde and 2% glutaraldehyde for disinfection of laryngoscopes: A prospective pilot study.Indian J Anaesth. 2017 Jun;61(6):490-493. doi: 10.4103/ija.IJA_22_17. Indian J Anaesth. 2017. PMID: 28655955 Free PMC article.
-
Nosocomial contamination of laryngoscope handles: challenging current guidelines.Anesth Analg. 2009 Aug;109(2):479-83. doi: 10.1213/ane.0b013e3181ac1080. Anesth Analg. 2009. PMID: 19608822 Free PMC article.
-
Bacterial Contamination and Disinfection Status of Laryngoscopes Stored in Emergency Crash Carts.J Prev Med Public Health. 2017;50(3):158-164. doi: 10.3961/jpmph.17.013. J Prev Med Public Health. 2017. PMID: 28605891 Free PMC article.
MeSH terms
LinkOut - more resources
Medical