Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2001 Jan;92(1):184-8.
doi: 10.1097/00000539-200101000-00035.

The dose-range effects of sufentanil added to 0.125% bupivacaine on the quality of patient-controlled epidural analgesia during labor

Affiliations
Clinical Trial

The dose-range effects of sufentanil added to 0.125% bupivacaine on the quality of patient-controlled epidural analgesia during labor

J M Bernard et al. Anesth Analg. 2001 Jan.

Abstract

To determine the minimal sufentanil concentration required to improve the quality of patient-controlled epidural analgesia during labor, we compared the efficacy of a combination of 0.125% bupivacaine with 1:800,000 epinephrine and different concentrations of sufentanil in a double-blinded randomized study. Concentrations were no sufentanil (n = 66), 0.078 microg/mL sufentanil (n = 65), 0.156 microg/mL sufentanil (n = 65), 0.312 microg/mL sufentanil (n = 65), and 0.468 microg/mL sufentanil (n = 67). The patient-controlled epidural analgesia setting was a 12-mL bolus dose and a 25-min lockout interval. Pain was scored at 5-6 cm, 7-8 cm, and full cervical dilation by using a 10-cm visual analog scale. At full cervical dilation, the pain scores were lower in the groups receiving a solution of at least 0.156 microg/mL sufentanil. Few differences were observed when using the larger concentrations, except for increased pruritus intensity. The duration of labor and the mode of delivery were similar in each group. Rescue analgesia, which consisted of 6 mL of 0.25% bupivacaine, was infrequent and comparable between groups. The use of the pump did not differ between groups. Adding a small concentration of sufentanil to 0.125% bupivacaine for patient-controlled epidural analgesia during labor improved the quality of analgesia but did not modify the bupivacaine requirement. Reducing the sufentanil concentrations to 0.156 microg/mL decreased the pruritus intensity without reducing analgesia.

Implications: Adding a small concentration of sufentanil to 0.125% bupivacaine for patient-controlled epidural analgesia during labor improved the quality of analgesia but did not modify the bupivacaine requirement. Reducing the sufentanil concentrations to 0.156 microg/mL decreased the pruritus intensity without reducing analgesia.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources