Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2001 Jan 1;19(1):127-36.
doi: 10.1200/JCO.2001.19.1.127.

Dose escalation in non-small-cell lung cancer using three-dimensional conformal radiation therapy: update of a phase I trial

Affiliations
Clinical Trial

Dose escalation in non-small-cell lung cancer using three-dimensional conformal radiation therapy: update of a phase I trial

J A Hayman et al. J Clin Oncol. .

Abstract

Purpose: High-dose radiation may improve outcomes in non-small-cell lung cancer (NSCLC). By using three-dimensional conformal radiation therapy and limiting the target volume, we hypothesized that the dose could be safely escalated.

Materials and methods: A standard phase I design was used. Five bins were created based on the volume of normal lung irradiated, and dose levels within bins were chosen based on the estimated risk of radiation pneumonitis. Starting doses ranged from 63 to 84 Gy given in 2.1-Gy fractions. Target volumes included the primary tumor and any nodes >or= 1 cm on computed tomography. Clinically uninvolved nodal regions were not included purposely. More recently, selected patients received neoadjuvant cisplatin and vinorelbine.

Results: At the time of this writing, 104 patients had been enrolled. Twenty-four had stage I, four had stage II, 43 had stage IIIA, 26 had stage IIIB, and seven had locally recurrent disease. Twenty-five received chemotherapy, and 63 were assessable for escalation. All bins were escalated at least twice. Although grade 2 radiation pneumonitis occurred in five patients, grade 3 radiation pneumonitis occurred in only two. The maximum-tolerated dose was only established for the largest bin, at 65.1 Gy. Dose levels for the four remaining bins were 102.9, 102.9, 84 and 75.6 Gy. The majority of patients failed distantly, though a significant proportion also failed in the target volume. There were no isolated failures in clinically uninvolved nodal regions.

Conclusion: Dose escalation in NSCLC has been accomplished safely in most patients using three-dimensional conformal radiation therapy, limiting target volumes, and segregating patients by the volume of normal lung irradiated.

PubMed Disclaimer

MeSH terms