Improvement of image resolution and quantitative accuracy in clinical Single Photon Emission Computed Tomography
- PMID: 11137790
- DOI: 10.1016/s0895-6111(00)00064-1
Improvement of image resolution and quantitative accuracy in clinical Single Photon Emission Computed Tomography
Abstract
Clinical Single Photon Emission Computed Tomography (SPECT) is a scanning technique which acquires gamma-camera images ('projections') over a range of angles around a patient. These projections allow the reconstruction of cross sectional ('tomographic') images of the gamma-radiating pharmaceutical distribution in the patient, thus providing interesting information about the functioning of organs and tissues.SPECT images are seriously affected by a variety of image degrading processes. Restrictions on the amount of radio-pharmaceutical that can be administered to a patient cause noise in the projections and the limited spatial resolution of the gamma-camera results in blurring of the projections. In addition to these image degradations, the reconstruction of cross-sections is complicated by Compton scattering of gamma-photons in tissue, which causes attenuation of the photon flux received by the gamma-camera and causes improper detection of photons which have been scattered in tissue. This results in some additional blurring and loss of accuracy of the SPECT images in predicting activity concentrations. Tremendous efforts have been made to improve the quantitative accuracy and the spatial resolution of SPECT, and to reduce the noise in the reconstructed images. These efforts have resulted in corrective reconstruction algorithms, which are generally based on incorporation of accurate models of the main image degrading factors. Improvements of the data acquisition hardware can further increase image quality. In this paper, the image formation process of SPECT, including image-degrading factors, is explained. In addition, reconstruction algorithms and hardware modifications are reviewed, and their effects on image quality are illustrated with physical phantom and simulation experiments.
Similar articles
-
Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system.J Nucl Med. 2005 May;46(5):868-77. J Nucl Med. 2005. PMID: 15872362 Clinical Trial.
-
Quantitative Monte Carlo-based holmium-166 SPECT reconstruction.Med Phys. 2013 Nov;40(11):112502. doi: 10.1118/1.4823788. Med Phys. 2013. PMID: 24320461
-
Quantification and reduction of the collimator-detector response effect in SPECT by applying a system model during iterative image reconstruction: a simulation study.Nucl Med Commun. 2012 Mar;33(3):228-38. doi: 10.1097/MNM.0b013e32834e755f. Nucl Med Commun. 2012. PMID: 22134173
-
Image distortion and correction in single photon emission CT.Ann Nucl Med. 2004 May;18(3):171-85. doi: 10.1007/BF02984998. Ann Nucl Med. 2004. PMID: 15233278 Review.
-
Absolute quantification in SPECT.Eur J Nucl Med Mol Imaging. 2011 May;38 Suppl 1:S69-77. doi: 10.1007/s00259-011-1770-8. Epub 2011 Apr 12. Eur J Nucl Med Mol Imaging. 2011. PMID: 21484383 Review.
Cited by
-
Monte carlo study of the effect of collimator thickness on T-99m source response in single photon emission computed tomography.World J Nucl Med. 2012 May;11(2):70-4. doi: 10.4103/1450-1147.103419. World J Nucl Med. 2012. PMID: 23372440 Free PMC article.
-
Comparison of methods for thyroid volume estimation in patients with Graves' disease.Eur J Nucl Med Mol Imaging. 2003 Apr;30(4):525-31. doi: 10.1007/s00259-002-1101-1. Epub 2003 Jan 23. Eur J Nucl Med Mol Imaging. 2003. PMID: 12541136 Clinical Trial.
-
A computational positron emission tomography simulation model for imaging beta-amyloid in mice.Mol Imaging Biol. 2005 Jan-Feb;7(1):69-77. doi: 10.1007/s11307-005-0952-9. Mol Imaging Biol. 2005. PMID: 15912278
-
Quantitative whole-body dynamic planar scintigraphy in mice with 99mTc and 161Tb.EJNMMI Phys. 2025 Jul 1;12(1):61. doi: 10.1186/s40658-025-00775-y. EJNMMI Phys. 2025. PMID: 40591183 Free PMC article.
-
Evaluation of Compton attenuation and photoelectric absorption coefficients by convolution of scattering and primary functions and counts ratio on energy spectra.Indian J Nucl Med. 2015 Jul-Sep;30(3):239-47. doi: 10.4103/0972-3919.158532. Indian J Nucl Med. 2015. PMID: 26170567 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources