Influence of posture, breathing pattern, and type of exercise on minute ventilation estimation by a pacemaker transthoracic impedance sensor
- PMID: 11139920
- DOI: 10.1111/j.1540-8159.2000.tb07015.x
Influence of posture, breathing pattern, and type of exercise on minute ventilation estimation by a pacemaker transthoracic impedance sensor
Abstract
Previous studies have shown a high correlation between transthoracic impedance minute ventilation (IMV) determined by a pacemaker sensor and actual minute ventilation (VE) measured by standard methods. We hypothesized that several factors (e.g., posture, breathing pattern, and exercise type) could potentially affect the calibration between IMV and VE. In patients with Medtronic Kappa 400 pacemakers, VE (L/min) was monitored using a standard cardiopulmonary metabolic gas analysis system with simultaneous recording of IMV (ohms/min) using DR-180 extended telemetry monitors. Effects of posture and of breathing pattern at rest (19 patients; age 60 +/- 13 years) were evaluated by monitoring each patient under three conditions: (a) slow breathing, supine, (b) slow breathing, sitting, and (c) shallow breathing, supine. Calibration at rest was defined as the ratio of IMV to VE. Effect of type of exercise on calibration compared treadmill versus graded bicycle ergometer exercise (18 patients; age 62 +/- 14 years). Calibration during exercise was defined as: (a) "Begin" (the IMV to VE ratio at VE = 10 L/min, the typical VE value at beginning of exercise), and (b) slope of the IMV/VE regression line. Calibration of IMV/VE was significantly smaller for sitting versus supine position (0.7130.177, P < 0.001) and for shallow versus slow breathing (0.7210.373, P < 0.001), and larger for treadmill versus bicycle exercise (Begin: 1.240.43, P = 0.018; Slope: 1.260.42, P = 0.013). In conclusion, posture, breathing pattern, and type of exercise affect the IMV estimation of the actual VE, possibly by altering the static or dynamic geometry (thus, the impedance) of the intrathoracic viscera.
Similar articles
-
Rate responsive pacing using transthoracic impedance minute ventilation sensors: a multicenter study on calibration stability.Pacing Clin Electrophysiol. 2002 Dec;25(12):1679-84. doi: 10.1046/j.1460-9592.2002.01679.x. Pacing Clin Electrophysiol. 2002. PMID: 12520667
-
Comparison of impedance minute ventilation and direct measured minute ventilation in a rate adaptive pacemaker.Pacing Clin Electrophysiol. 2003 Nov;26(11):2127-33. doi: 10.1046/j.1460-9592.2003.00331.x. Pacing Clin Electrophysiol. 2003. PMID: 14622315
-
Correlation of impedance minute ventilation with measured minute ventilation in a rate responsive pacemaker.Pacing Clin Electrophysiol. 2001 Jun;24(6):989-93. doi: 10.1046/j.1460-9592.2001.00989.x. Pacing Clin Electrophysiol. 2001. PMID: 11449596
-
The "low intensity treadmill exercise" protocol for appropriate rate adaptive programming of minute ventilation controlled pacemakers.Pacing Clin Electrophysiol. 1995 Jul;18(7):1374-87. doi: 10.1111/j.1540-8159.1995.tb02599.x. Pacing Clin Electrophysiol. 1995. PMID: 7567590
-
Initial clinical experience with a new dual sensor SSIR pacemaker controlled by body activity and minute ventilation.Pacing Clin Electrophysiol. 1995 Aug;18(8):1487-95. doi: 10.1111/j.1540-8159.1995.tb06735.x. Pacing Clin Electrophysiol. 1995. PMID: 7479170
Cited by
-
Sensors for rate responsive pacing.Indian Pacing Electrophysiol J. 2004 Jul 1;4(3):137-45. Indian Pacing Electrophysiol J. 2004. PMID: 16943981 Free PMC article.
-
Seasonal influence on sleep apnoea recorded daily by pacemakers.Sleep Breath. 2023 Dec;27(6):2181-2189. doi: 10.1007/s11325-023-02789-1. Epub 2023 Mar 27. Sleep Breath. 2023. PMID: 36973595
-
Rate-Responsive Cardiac Pacing: Technological Solutions and Their Applications.Sensors (Basel). 2023 Jan 27;23(3):1427. doi: 10.3390/s23031427. Sensors (Basel). 2023. PMID: 36772467 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical