Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2000 Nov;23(11 Pt 2):1908-10.
doi: 10.1111/j.1540-8159.2000.tb07050.x.

Resumption of right atrial isthmus conduction following atrial flutter radiofrequency ablation

Affiliations
Clinical Trial

Resumption of right atrial isthmus conduction following atrial flutter radiofrequency ablation

P Bru et al. Pacing Clin Electrophysiol. 2000 Nov.

Abstract

Right atrial isthmus block is currently accepted as a success criterion of atrial flutter ablation. An electrophysiological study performed days after the ablation procedure may show recovery of conduction across the isthmus in some patients, followed by arrhythmia recurrence. However, few data are available on the time course of this recovery and on the monitoring of isthmus conduction at the end of the ablation procedure as a means of increasing the success rate of the procedure. Radiofrequency (RF) catheter ablation was performed in 28 men and 7 women (mean age = 65 +/- 11 years) presenting with common or clockwise atrial flutter (AFL) resistant to 2.9 +/- 1.8 antiarrhythmic drugs. Underlying heart disease was present in 13 patients. The ablation procedure was performed with an 8-mm-tip catheter, by several 45-second applications at a target temperature of 65 degrees C, directed to the isthmus between tricuspid annulus and inferior vena cava. Bidirectional isthmus block (BDB) was created with 4-24 RF applications in all but one patient. Special attention was paid to exclude incomplete block by meticulous mapping during pacing at the coronary sinus os and at the low lateral right atrium every 5 minutes for 20 minutes thereafter. Conduction recovered across the isthmus in 5 patients at 10, 10, 12, 15, and 16 minutes, respectively, and further RF applications were needed to obtain stable block. At a follow-up of 17 +/- 10 months, AFL occurred in the patient without, and in one patient with BDB. Thirty-three of the 34 patients (97%) with persistent BDB remained free of arrhythmia recurrence. This study showed that conduction resumed across the isthmus within 20 minutes, after AFL ablation in 15% of the patients. The long-term results of the procedure can be optimized by ascertaining the persistence of BDB during that period of time.

PubMed Disclaimer

Publication types

LinkOut - more resources