Comparative Study
. 2000 Dec;4(4):645-54.
doi: 10.1023/a:1026586119600.

Electrode impedance: an indicator of electrode-tissue contact and lesion dimensions during linear ablation

Affiliations
Comparative Study

Electrode impedance: an indicator of electrode-tissue contact and lesion dimensions during linear ablation

X Zheng et al. J Interv Card Electrophysiol. 2000 Dec.

Abstract

Pre-ablation impedance was evaluated for its ability to detect electrode-tissue contact and allow creation of long uniform linear lesions with a multi-electrode ablation catheter. The study consisted of 2 parts, both of which used the in vivopig thigh muscle model. In part 1, a 7 Fr. multi-electrode catheter was held in 3 electrode-tissue contact conditions: (1) non-contact; (2) light contact with a 30g downward force; and (3) tight contact with a 90g downward force. Impedances were measured in unipolar, modified unipolar and bipolar configurations using a source with frequencies from 100Hz to 500kHz. Compared with non-contact, the impedance increased 35 +/- 22 % with 30g contact pressure and 68 +/- 40% when the contact pressure was increased to 90g across the range of frequencies studied. In part 2, the same catheter was held against the tissue with different forces. Pre-ablation impedance was measured using a 10kHz current. Phased radiofrequency energy was applied to the 5 electrodes simultaneously using 10W power at each electrode for 120s. A total of 32 linear lesions were created. The lesion dimensions correlated with pre-ablation impedance. A unipolar impedance > or = 190 Omega indicates 95% possibility to create a uniform linear lesion of at least 3mm depth with our ablation system. We conclude that pre-ablation impedance may be a useful indicator for predicting electrode-tissue contact and the ability to create a continuous and transmural linear lesion with a multi-electrode catheter.

PubMed Disclaimer

References

    1. Pacing Clin Electrophysiol. 1990 Oct;13(10):1242-8 - PubMed
    1. Circulation. 1997 Oct 21;96(8):2715-21 - PubMed
    1. Pacing Clin Electrophysiol. 1989 Jun;12(6):962-76 - PubMed
    1. Circulation. 1995 Apr 15;91(8):2264-73 - PubMed
    1. J Cardiovasc Electrophysiol. 1996 Dec;7(12 ):1132-44 - PubMed

Publication types

LinkOut - more resources