Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2000 Dec;38(12):528-34.
doi: 10.1093/chromsci/38.12.528.

Solid-phase microextraction and headspace solid-phase microextraction for the determination of high molecular-weight polycyclic aromatic hydrocarbons in water and soil samples

Affiliations

Solid-phase microextraction and headspace solid-phase microextraction for the determination of high molecular-weight polycyclic aromatic hydrocarbons in water and soil samples

R Doong et al. J Chromatogr Sci. 2000 Dec.

Abstract

The feasibility of direct-immersion (DI) solid-phase microextraction (SPME) and headspace (HS) SPME for the determination of high-ring polycyclic aromatic hydrocarbons (PAHs) (4- to 6-ring PAHs) in water and soil samples is studied. Three SPME fibers--100- and 30-microm polydimethylsiloxane (PDMS) and 85-microm polyacrylate (PA) fibers-are compared for the effective extraction of PAHs. Parameters affecting the sorption of PAHs into the fiber such as sampling time, sampling volume, and temperature are also evaluated. The extracted amounts of high-ring PAHs decrease with the decreasing of film thickness, and the 100-microm PDMS has the highest extraction efficiency than 85-microm PA and 30-microm PDMS fibers. Also, the extraction efficiency decreases with the increasing molecular weights of PAHs. Of the 10 high-ring PAHs, only fluoranthene and pyrene can reach equilibrium within 120 min at 25 degrees C for DI-SPME in a water sample. Increasing the temperature to 60 degrees C can increase the sensitivity of PAHs and shorten the equilibrium time. A 0.7- to 25-fold increase in peak area is obtained for DI-SPME when the working temperature is increased to 60 degrees C. For HS-SPME, the extraction efficiency of PAHs decrease when the headspace volume of the sampling system increases. All high-ring PAHs can be detected in a water sample by increasing the temperature to 80 degrees C. However, only 4- and 5-ring PAHs can be quantitated in a CRM soil sample when HS-SPME is used. The addition of a surfactant with high hydrophilic property can effectively enhance the sensitivity of high-ring PAHs. HS-SPME as well as DI-SPME with 100-microm PDMS or 85-microm PA fibers are shown to be suitable methods for analyzing high-ring PAHs in a water sample; however, this technique can only apply in a soil sample for PAHs having up to 5 rings.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources