Solid-phase microextraction and headspace solid-phase microextraction for the determination of high molecular-weight polycyclic aromatic hydrocarbons in water and soil samples
- PMID: 11144512
- DOI: 10.1093/chromsci/38.12.528
Solid-phase microextraction and headspace solid-phase microextraction for the determination of high molecular-weight polycyclic aromatic hydrocarbons in water and soil samples
Abstract
The feasibility of direct-immersion (DI) solid-phase microextraction (SPME) and headspace (HS) SPME for the determination of high-ring polycyclic aromatic hydrocarbons (PAHs) (4- to 6-ring PAHs) in water and soil samples is studied. Three SPME fibers--100- and 30-microm polydimethylsiloxane (PDMS) and 85-microm polyacrylate (PA) fibers-are compared for the effective extraction of PAHs. Parameters affecting the sorption of PAHs into the fiber such as sampling time, sampling volume, and temperature are also evaluated. The extracted amounts of high-ring PAHs decrease with the decreasing of film thickness, and the 100-microm PDMS has the highest extraction efficiency than 85-microm PA and 30-microm PDMS fibers. Also, the extraction efficiency decreases with the increasing molecular weights of PAHs. Of the 10 high-ring PAHs, only fluoranthene and pyrene can reach equilibrium within 120 min at 25 degrees C for DI-SPME in a water sample. Increasing the temperature to 60 degrees C can increase the sensitivity of PAHs and shorten the equilibrium time. A 0.7- to 25-fold increase in peak area is obtained for DI-SPME when the working temperature is increased to 60 degrees C. For HS-SPME, the extraction efficiency of PAHs decrease when the headspace volume of the sampling system increases. All high-ring PAHs can be detected in a water sample by increasing the temperature to 80 degrees C. However, only 4- and 5-ring PAHs can be quantitated in a CRM soil sample when HS-SPME is used. The addition of a surfactant with high hydrophilic property can effectively enhance the sensitivity of high-ring PAHs. HS-SPME as well as DI-SPME with 100-microm PDMS or 85-microm PA fibers are shown to be suitable methods for analyzing high-ring PAHs in a water sample; however, this technique can only apply in a soil sample for PAHs having up to 5 rings.
Similar articles
-
Solid-phase microextraction for determining the distribution of sixteen US Environmental Protection Agency polycyclic aromatic hydrocarbons in water samples.J Chromatogr A. 2000 May 26;879(2):177-88. doi: 10.1016/s0021-9673(00)00347-2. J Chromatogr A. 2000. PMID: 10893034
-
Quantitative determination of 16 polycyclic aromatic hydrocarbons in soil samples using solid-phase microextraction.J Sep Sci. 2009 Nov;32(22):3951-7. doi: 10.1002/jssc.200900420. J Sep Sci. 2009. PMID: 19842124
-
Determination of polycyclic aromatic hydrocarbons in solid matrices using automated cold fiber headspace solid phase microextraction technique.J Chromatogr A. 2013 Sep 13;1307:66-72. doi: 10.1016/j.chroma.2013.07.110. Epub 2013 Aug 6. J Chromatogr A. 2013. PMID: 23942478
-
Determination of chemical warfare agents and related compounds in environmental samples by solid-phase microextraction with gas chromatography.J Chromatogr A. 2011 Nov 25;1218(47):8457-79. doi: 10.1016/j.chroma.2011.09.066. Epub 2011 Oct 1. J Chromatogr A. 2011. PMID: 22015307 Review.
-
Headspace-solid-phase microextraction in the analysis of the volatile fraction of aromatic and medicinal plants.J Chromatogr Sci. 2006 Aug;44(7):416-29. doi: 10.1093/chromsci/44.7.416. J Chromatogr Sci. 2006. PMID: 16925939 Review.
Cited by
-
Characterization of a Microbial Consortium for the Bioremoval of Polycyclic Aromatic Hydrocarbons (PAHs) in Water.Int J Environ Res Public Health. 2018 May 13;15(5):975. doi: 10.3390/ijerph15050975. Int J Environ Res Public Health. 2018. PMID: 29757264 Free PMC article.
-
Determination of total and available fractions of PAHs by SPME in oily wastewaters: overcoming interference from NAPL and NOM.Environ Sci Pollut Res Int. 2009 Sep;16(6):671-8. doi: 10.1007/s11356-009-0118-4. Epub 2009 Mar 17. Environ Sci Pollut Res Int. 2009. PMID: 19290560
-
Optimisation of Urine Sample Preparation for Headspace-Solid Phase Microextraction Gas Chromatography-Mass Spectrometry: Altering Sample pH, Sulphuric Acid Concentration and Phase Ratio.Metabolites. 2020 Nov 25;10(12):482. doi: 10.3390/metabo10120482. Metabolites. 2020. PMID: 33255680 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources