Utility of the BACTEC Myco/F lytic medium for the detection of mycobacteria in blood
- PMID: 11146247
- DOI: 10.1016/s0732-8893(00)00202-9
Utility of the BACTEC Myco/F lytic medium for the detection of mycobacteria in blood
Abstract
This study aims to evaluate the performance of a new vial (Myco/F Lytic) for the detection of mycobacteria from blood specimens. This vial is monitored in the BACTEC 9000 blood culture system. We compared it with the traditional method routinely used in our laboratory, which is a lysis-centrifugation based procedure. Of 275 samples tested in parallel by both methods, 23 from 20 patients grew mycobacteria (18 Mycobacterium avium complex, 4 M. tuberculosis and 1 M. simiae); 11 isolates were recovered using both systems, 12 were isolated with the Myco/F Lytic medium only, and none were isolated using the traditional method only (p < 0.05). Blood was the diagnostic sample for 12 patients with the Myco/F Lytic system and only 7 with the traditional system. The mean time to detection of mycobacteria with Myco/F Lytic medium was 17 days, whereas it was 44 days with the traditional method (p < 0.001). Identification by DNA probes was performed directly from the Myco/F Lytic bottle. Myco/F Lytic is a rapid, simple, safe and highly reliable diagnostic method for the detection of mycobacteria in blood.
Similar articles
-
Evaluation of BACTEC MYCO/F lytic medium for recovery of mycobacteria and fungi from blood.J Clin Microbiol. 1998 May;36(5):1176-9. doi: 10.1128/JCM.36.5.1176-1179.1998. J Clin Microbiol. 1998. PMID: 9574671 Free PMC article.
-
Comparison of the BACTEC MYCO/F Lytic bottle to the isolator tube, BACTEC Plus Aerobic F/bottle, and BACTEC Anaerobic Lytic/10 bottle and comparison of the BACTEC Plus Aerobic F/bottle to the Isolator tube for recovery of bacteria, mycobacteria, and fungi from blood.J Clin Microbiol. 2001 Dec;39(12):4380-6. doi: 10.1128/JCM.39.12.4380-4386.2001. J Clin Microbiol. 2001. PMID: 11724848 Free PMC article.
-
Controlled comparison of BACTEC 13A, MYCO/F LYTIC, BacT/ALERT MB, and ISOLATOR 10 systems for detection of mycobacteremia.J Clin Microbiol. 2003 May;41(5):1987-90. doi: 10.1128/JCM.41.5.1987-1990.2003. J Clin Microbiol. 2003. PMID: 12734238 Free PMC article. Clinical Trial.
-
Laboratory detection of mycobacteremia.Clin Lab Med. 1994 Mar;14(1):99-105. Clin Lab Med. 1994. PMID: 8181238 Review.
-
[Standardization of laboratory tests for tuberculosis and their proficiency testing].Kekkaku. 2003 Aug;78(8):541-51. Kekkaku. 2003. PMID: 14509226 Review. Japanese.
Cited by
-
Evaluation of the efficacy of Myco/F lytic system, MGIT960 system and Lowenstein-Jensen medium for recovery of Mycobacterium tuberculosis from sterile body fluids.Sci Rep. 2016 Nov 23;6:37757. doi: 10.1038/srep37757. Sci Rep. 2016. PMID: 27876877 Free PMC article.
-
Specificities and functions of the recA and pps1 intein genes of Mycobacterium tuberculosis and application for diagnosis of tuberculosis.J Clin Microbiol. 2002 Mar;40(3):943-50. doi: 10.1128/JCM.40.3.943-950.2002. J Clin Microbiol. 2002. PMID: 11880421 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical