Nuclear image morphometry and cytologic grade of breast carcinoma
- PMID: 11147303
Nuclear image morphometry and cytologic grade of breast carcinoma
Abstract
Objective: To correlate visual cytologic grade with automated nuclear morphometry of carcinoma of the breast.
Study design: We randomly selected 24 histologically proven infiltrating ductal carcinomas of the breast and 10 benign breast lesions (fibroadenoma). Hematoxylin-eosin-stained fine needle aspiration cytology (FNAC) smears were selected for both cytologic grade and automated image morphometry. The same hematoxylin-eosin-stained FNAC smears were studied for area, convex area, standard deviation of nuclear area, diameter, perimeter and convex perimeters of nucleus. At least 100 cells from each case were measured with an image cytometer.
Results: Mean nuclear area, standard deviation of nuclear area, nuclear diameter, convex area, convex perimeter and perimeter were significantly increased from benign versus grade 1 carcinomas and grade 1 versus grade 2 and 3 carcinomas (one way ANOVA test). However, there was no significant difference in grade 2 versus grade 3 carcinomas.
Conclusion: Automated image cytometry rapidly and successfully measures various nuclear parameters. The measurement of various nuclear parameters would be helpful in future applications of automated diagnosis and grading of breast carcinomas from cytologic material.
Similar articles
-
Automated image morphometry of lobular breast carcinoma.Anal Quant Cytol Histol. 2002 Apr;24(2):81-4. Anal Quant Cytol Histol. 2002. PMID: 12026054
-
Cytologic grading and DNA image cytometry of breast carcinoma on fine needle aspiration cytology smears.Anal Quant Cytol Histol. 1999 Feb;21(1):17-20. Anal Quant Cytol Histol. 1999. PMID: 10068770
-
Automated nuclear image morphometry on fine needle aspiration smears of malignant round cell tumors.Anal Quant Cytol Histol. 2001 Aug;23(4):287-90. Anal Quant Cytol Histol. 2001. PMID: 11531143
-
Fractal dimension in aspiration cytology smears of breast and cervical lesions.Anal Quant Cytol Histol. 2004 Apr;26(2):109-12. Anal Quant Cytol Histol. 2004. PMID: 15131899
-
Fine needle aspiration cytology of the breast: impact of experience on accuracy, using standardized cytologic criteria.Acta Cytol. 2008 Mar-Apr;52(2):145-51. doi: 10.1159/000325472. Acta Cytol. 2008. PMID: 18499986 Review.
Cited by
-
Significance of nuclear morphometry in cytological aspirates of breast masses.J Cytol. 2010 Jan;27(1):16-21. doi: 10.4103/0970-9371.66694. J Cytol. 2010. PMID: 21042529 Free PMC article.
-
Study of nuclear morphometry on cytology specimens of benign and malignant breast lesions: A study of 122 cases.J Cytol. 2017 Jan-Mar;34(1):10-15. doi: 10.4103/0970-9371.197591. J Cytol. 2017. PMID: 28182052 Free PMC article.
-
Heterogeneity Between Ducts of the Same Nuclear Grade Involved by Duct Carcinoma In Situ (DCIS) of the Breast.Cancer Inform. 2010 Sep 7;9:209-16. doi: 10.4137/cin.s5505. Cancer Inform. 2010. PMID: 20981137 Free PMC article.
-
Significance of Nuclear Morphometry in Breast Lesions: A Cross-Sectional Study.Cureus. 2023 May 23;15(5):e39378. doi: 10.7759/cureus.39378. eCollection 2023 May. Cureus. 2023. PMID: 37378137 Free PMC article.
-
Effect of quantitative nuclear image features on recurrence of Ductal Carcinoma In Situ (DCIS) of the breast.Cancer Inform. 2008;6:99-109. doi: 10.4137/cin.s401. Epub 2008 Mar 1. Cancer Inform. 2008. PMID: 18779878 Free PMC article.
MeSH terms
LinkOut - more resources
Medical