Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2001 Jan;15(1):10-7.
doi: 10.1097/00005131-200101000-00003.

Safe placement of proximal tibial transfixation wires with respect to intracapsular penetration

Affiliations
Comparative Study

Safe placement of proximal tibial transfixation wires with respect to intracapsular penetration

J S Reid et al. J Orthop Trauma. 2001 Jan.

Abstract

Objectives: To determine the safe zone for transfixation wires in the proximal tibia to avoid intracapsular penetration.

Methods: The material consisted of five fresh cadaver knees (two paired) and seven knees of volunteer subjects (three paired). High-resolution magnetic resonance imaging (MRI) was performed on each knee after distension with a gadolinium solution. The distance d from the subchondral bone to the insertion of the reflected joint capsule was measured. Selected cadaver knees were then anatomically sectioned to correlate the MRI findings with anatomic measurements.

Results: On the anteromedial side of the knee, the distance from the reflected joint capsule to the subchondral bone was less than eleven millimeters in all specimens except one. Posteromedially, d was smaller and ranged from two to four millimeters. On the lateral side of the knee anterior to the proximal tibiofibular joint, this distance ranged from six to nine millimeters. In all knees but two, d was greatest at the posterior aspect of the proximal tibiofibular joint, ranging from eight to thirteen millimeters. In one volunteer knee, the septum that separates the knee joint from the proximal tibiofibular joint was either torn or attenuated, resulting in complete communication between these two synovial cavities.

Conclusions: Proximal tibial transfixation wires away from the tibiofibular joint are likely to be extraarticular if kept greater than fourteen millimeters from the subchondral bone. In the region of the proximal tibiofibular joint, a safe distance is unclear because it is difficult to know preoperatively which knee has a torn septum.

PubMed Disclaimer

Publication types

LinkOut - more resources