Objective: To evaluate the feasibility of short automated static perimetry using tendency-oriented perimetry in the pediatric population.
Design: Prospective observational case series.
Participants: Fifty normal children age 6 through 12 years.
Testing: Subjects underwent testing with the Octopus TOP-32 program on the Octopus 1-2-3 automated perimeter. Testing was performed in a typical clinical setting without adaptations to the perimeter, prolonged training, or the use of custom seating. Each eye was tested twice.
Main outcome measures: Ability to complete automated static perimetry tests with both eyes. Mean sensitivity, mean defect, and loss of variance; gray scale and numeric representations of the field; duration of each test and of the entire session; subjective assessment of each test as normal or abnormal; calculation of test specificity. Comparisons by age and test number were performed.
Results: All subjects successfully completed all four tests. The mean duration for each test was 2:30+/- 0.23 minutes. The average time for the whole session, including training, testing both eyes twice, and rest periods, was 25.8+/-4.87 minutes. Improvement in the specificity of the test (fewer abnormal tests in normal children) occurred in direct relation to subject age (R = 0.5).
Conclusions: Automated static perimetry using short, tendency-oriented programs can be successfully performed in normal children age 6 through 12 years in a typical clinical setting. Age was the best predictor of the mean sensitivity, reproducibility, and accuracy of the test, with the most reliable results obtained after 7 years of age. In children 6 to 7 years old, significant interindividual variability was present, and testing success was more dependent on the child's maturity and ability to concentrate. Short automated perimetry seems to be a promising tool for the evaluation of peripheral vision in pediatric patients.
Similar articles
-
Feasibility and outcome of automated kinetic perimetry in children.Graefes Arch Clin Exp Ophthalmol. 2010 Oct;248(10):1493-500. doi: 10.1007/s00417-010-1342-9. Epub 2010 Mar 16. Graefes Arch Clin Exp Ophthalmol. 2010. PMID: 20232076
-
Comparison of Quality and Output of Different Optimal Perimetric Testing Approaches in Children With Glaucoma.JAMA Ophthalmol. 2018 Feb 1;136(2):155-161. doi: 10.1001/jamaophthalmol.2017.5898. JAMA Ophthalmol. 2018. PMID: 29285534 Free PMC article.
-
Feasibility and outcome of automated static perimetry in children using continuous light increment perimetry (CLIP) and fast threshold strategy.Acta Ophthalmol Scand. 2005 Dec;83(6):664-9. doi: 10.1111/j.1600-0420.2005.00526.x. Acta Ophthalmol Scand. 2005. PMID: 16396642
-
Techniques and developments in automated perimetry: a review.Ophthalmic Physiol Opt. 1988;8(3):295-308. doi: 10.1016/0275-5408(88)90180-9. Ophthalmic Physiol Opt. 1988. PMID: 3077648 Review.
-
The diagnostic accuracy and feasibility of paediatric visual field tests: A systematic review.Ophthalmic Physiol Opt. 2025 May;45(3):726-741. doi: 10.1111/opo.13449. Epub 2025 Jan 28. Ophthalmic Physiol Opt. 2025. PMID: 39873237
Cited by
-
Feasibility, Accuracy, and Repeatability of Suprathreshold Saccadic Vector Optokinetic Perimetry.Transl Vis Sci Technol. 2016 Aug 31;5(4):15. doi: 10.1167/tvst.5.4.15. eCollection 2016 Aug. Transl Vis Sci Technol. 2016. PMID: 27617181 Free PMC article.
-
Maintaining fixation by children in a virtual reality version of pupil perimetry.J Eye Mov Res. 2022 Sep 19;15(3):10.16910/jemr.15.3.2. doi: 10.16910/jemr.15.3.2. eCollection 2022. J Eye Mov Res. 2022. PMID: 37091859 Free PMC article.
-
Effects of Stimulus Luminance, Stimulus Color and Intra-Stimulus Color Contrast on Visual Field Mapping in Neurologically Impaired Adults Using Flicker Pupil Perimetry.Eye Brain. 2023 Jun 2;15:77-89. doi: 10.2147/EB.S409905. eCollection 2023. Eye Brain. 2023. PMID: 37287993 Free PMC article.
-
Feasibility and outcome of automated kinetic perimetry in children.Graefes Arch Clin Exp Ophthalmol. 2010 Oct;248(10):1493-500. doi: 10.1007/s00417-010-1342-9. Epub 2010 Mar 16. Graefes Arch Clin Exp Ophthalmol. 2010. PMID: 20232076
-
Normal values for Octopus tendency oriented perimetry in children 7 through 13 years old.Graefes Arch Clin Exp Ophthalmol. 2005 Sep;243(9):886-93. doi: 10.1007/s00417-005-1134-9. Epub 2005 Apr 15. Graefes Arch Clin Exp Ophthalmol. 2005. PMID: 15834603
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources