Intravascular ultrasound criteria for the assessment of the functional significance of intermediate coronary artery stenoses and comparison with fractional flow reserve
- PMID: 11152827
- DOI: 10.1016/s0002-9149(00)01304-7
Intravascular ultrasound criteria for the assessment of the functional significance of intermediate coronary artery stenoses and comparison with fractional flow reserve
Abstract
The functional significance of coronary artery stenoses of intermediate severity is important in determining strategy in patient care. Intravascular ultrasound (IVUS) is often used to evaluate coronary stenosis severity. However, at present, few data are available about the role IVUS in the assessment of functional significance of intermediate lesions. Myocardial fractional flow reserve (FFR) <0.75 is a reliable index of a functionally severe coronary stenosis. In 53 lesions we assessed (1) by pressure wire: FFR (index of functional significance), and (2) by IVUS: minimal lumen cross-sectional area (MLA, square millimeters), minimal lumen diameter (MLD, millimeters), lesion length (millimeters), and percent area stenosis at the lesion site. By regression analysis, percent area stenosis and lesion length had a significant inverse correlation with FFR (r = -0.58, p <0.001, r = -0.41, p <0.004, respectively). MLD and MLA showed a significant positive relation with FFR (r = 0.51, p <0.001, r = 0.41, p <0.004, respectively). By using a receiver operating characteristic (ROC) curve, we identified a percent area stenosis > 70% (sensitivity 100%, specificity 68%), a MLD < or = 1.8 mm (sensitivity 100%, specificity 66%), a MLA < or =4.0 mm2 (sensitivity 92%, specificity 56%), and a lesion length of >10 mm (sensitivity 41%, specificity 80%) to be the best cut-off values to fit with a FFR <0.75. The combined evaluation of both percent area stenosis and MLD made the IVUS examination more specific (sensitivity 100%, specificity 76%). In 53 intermediate coronary lesions found by angiography, IVUS area stenosis >70%, MLD < or =1.8 mm, MLA < or =4.0 mm2, and lesion length > 10 mm reliably identified functionally critical intermediate coronary stenoses.
Similar articles
-
Intravascular ultrasound lumen area parameters for assessment of physiological ischemia by fractional flow reserve in intermediate coronary artery stenosis.Cardiovasc Revasc Med. 2012 May-Jun;13(3):177-82. doi: 10.1016/j.carrev.2011.12.003. Epub 2012 Feb 14. Cardiovasc Revasc Med. 2012. PMID: 22336532
-
The role of intravascular ultrasound and quantitative angiography in the functional assessment of intermediate coronary lesions: correlation with fractional flow reserve.Cardiovasc Revasc Med. 2014 Jan;15(1):3-7. doi: 10.1016/j.carrev.2013.11.002. Epub 2013 Dec 10. Cardiovasc Revasc Med. 2014. PMID: 24444471
-
Correlation between fractional flow reserve and intravascular ultrasound lumen area in intermediate coronary artery stenosis.EuroIntervention. 2011 Jun;7(2):225-33. doi: 10.4244/EIJV7I2A37. EuroIntervention. 2011. PMID: 21646065
-
Diagnostic accuracy of intravascular ultrasound-derived minimal lumen area compared with fractional flow reserve--meta-analysis: pooled accuracy of IVUS luminal area versus FFR.Catheter Cardiovasc Interv. 2014 Sep 1;84(3):377-85. doi: 10.1002/ccd.25047. Epub 2014 Apr 22. Catheter Cardiovasc Interv. 2014. PMID: 23737441 Review.
-
Optical coherence tomography enables more accurate detection of functionally significant intermediate non-left main coronary artery stenoses than intravascular ultrasound: A meta-analysis of 6919 patients and 7537 lesions.Int J Cardiol. 2020 Feb 15;301:226-234. doi: 10.1016/j.ijcard.2019.09.067. Epub 2019 Oct 9. Int J Cardiol. 2020. PMID: 31677827
Cited by
-
Discordance Between Angiographic Assessment and Fractional Flow Reserve or Intravascular Ultrasound in Intermediate Coronary Lesions: A Post-hoc Analysis of the FLAVOUR Trial.Korean Circ J. 2024 Aug;54(8):485-496. doi: 10.4070/kcj.2024.0046. Epub 2024 Jun 10. Korean Circ J. 2024. PMID: 38956940 Free PMC article.
-
Comparison between instantaneous wave-free ratio versus morphometric assessments by intracoronary imaging.Heart Vessels. 2019 Jun;34(6):926-935. doi: 10.1007/s00380-018-1320-4. Epub 2018 Dec 7. Heart Vessels. 2019. PMID: 30535756
-
Prospective, head-to-head comparison of quantitative coronary angiography, quantitative computed tomography angiography, and intravascular ultrasound for the prediction of hemodynamic significance in intermediate and severe lesions, using fractional flow reserve as reference standard (from the ATLANTA I and II Study).Am J Cardiol. 2014 Jan 1;113(1):23-9. doi: 10.1016/j.amjcard.2013.09.010. Epub 2013 Oct 2. Am J Cardiol. 2014. PMID: 24238960 Free PMC article.
-
Optical coherence tomography: from research to practice.Eur Heart J Cardiovasc Imaging. 2012 May;13(5):370-84. doi: 10.1093/ehjci/jes025. Epub 2012 Feb 13. Eur Heart J Cardiovasc Imaging. 2012. PMID: 22330231 Free PMC article. Review.
-
When Functional Assessment Meets Intravascular Imaging in Patients with Coronary Artery Disease.J Cardiovasc Dev Dis. 2025 Aug 20;12(8):319. doi: 10.3390/jcdd12080319. J Cardiovasc Dev Dis. 2025. PMID: 40863385 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources