Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2000 Dec;6(12):4733-8.

Multi-institutional validation study of carboplatin dosing formula using adjusted serum creatinine level

Affiliations
  • PMID: 11156227
Multicenter Study

Multi-institutional validation study of carboplatin dosing formula using adjusted serum creatinine level

M Ando et al. Clin Cancer Res. 2000 Dec.

Abstract

Creatinine clearance (Ccr) is widely used as a practical substitute for glomerular filtration rate (GFR) in the Calvert formula: carboplatin dose (mg) = target area under the concentration versus time curve (AUC, mg ml(-1) min) x [GFR (ml min(-1)) + 25]. However, it causes systematic overdosing when the creatinine levels are measured by an enzymatic peroxidase-antiperoxidase method (PAP-Cr). We previously suggested an amended dosing formula to adjust this overdosing: carboplatin dose (mg) = AUC (mg ml(-1) min) x [adjusted Ccr (ml min(-1)) + 25], where the Ccr was adjusted by adding 0.2 (mg dl(-1)) to serum PAP-Cr. In this study, we prospectively validated this formula in 55 patients from six institutions. Target AUC ranged from 3 to 7 mg ml(-1) min, and Ccr was measured by 24-h urine collection. Estimation of carboplatin clearance with the amended formula was unbiased [mean prediction error (MPE) +/- SE = 2.9 +/- 3.4%] and acceptably precise [root mean squared error, (RMSE) = 24.7%], whereas the Calvert formula using non-adjusted Ccr overpredicted carboplatin clearance systematically (MPE +/- SE = 24.9 +/- 4.9% and RMSE = 36.1%). The improvement in the bias and precision of the estimation was seen in all of the participating institutions as shown by decrease in the absolute value of MPE and RMSE for each institution. The Chatelut formula also highly overestimated carboplatin clearance when PAP-Cr was used, but the adjustment of PAP-Cr yielded a decrease in MPE by 30.4% and in RMSE by 21.3%. These results confirmed the necessity of adjusting the serum PAP-Cr in carboplatin dosing formulas.

PubMed Disclaimer

Publication types

LinkOut - more resources