Antithrombotic therapy in patients with mechanical and biological prosthetic heart valves
- PMID: 11157651
- DOI: 10.1378/chest.119.1_suppl.220s
Antithrombotic therapy in patients with mechanical and biological prosthetic heart valves
Erratum in
- Chest 2001 Sep;120(3):1044
Abstract
1. Permanent therapy with oral anticoagulants offers the most consistent protection in patients with mechanical heart valves. 2. Antiplatelet agents alone do not consistently protect patients with mechanical prosthetic heart valves, including patients in sinus rhythm with St. Jude Medical valves in the aortic position. 3. Levels of oral anticoagulants that prolong the INR to 2.0 to 3.0 appear satisfactory for patients with St. Jude Medical bileaflet and Medtronic-Hall tilting disk mechanical valves in the aortic position, provided they are in sinus rhythm and the left atrium is not enlarged. Presumably, this is also true for the CarboMedics bileaflet valve, based on the observation of no clinically important difference in the rate of systemic embolism with this valve and the St. Jude Medical bileaflet valve. 4. Levels of oral anticoagulants that prolong the INR to 2.5 to 3.5 are satisfactory for tilting disk valves and bileaflet prosthetic valves in the mitral position. 5. Experience in patients with caged ball valves who had prothrombin time ratios reported in terms of the INR is sparse, because few such valves have been inserted in recent years. The number of surviving patients with caged ball valves continues to decrease. It has been suggested that the most advantageous level of the INR in patients with caged ball or caged disk valves should be as high as 4.0 to 4.9. However, others have shown a high rate of major hemorrhage with an INR that is even somewhat lower, 3.0-4.5. The problem is self-limited, however, because few such valves are being inserted. 6. In patients with mechanical heart valves, aspirin, in addition to oral anticoagulants, has been shown to diminish the frequency of thromboemboli. The risk of bleeding is somewhat increased if the INR is 2.0 to 3.0 or 2.5 to 3.5. However, if the INR is 3.0 to 4.5, the risk of bleeding becomes excessive with aspirin. There are no investigations in which aspirin 80 mg/d in combination with oral anticoagulants was evaluated. 7. Data are insufficient to recommend dipyridamole over low doses of aspirin in combination with warfarin. Whether dipyridamole plus aspirin is more effective than aspirin alone when used with warfarin is undetermined. 8. Patients with bioprosthetic valves in the mitral position as well as patients with bioprosthetic valves in the aortic position may be at risk for thromboemboli during the first 3 months after operation. 9. Among patients with bioprosthetic valves in the mitral position, oral anticoagulants at an INR of 2.0 to 2.3 were as effective as an INR of 2.5 to 4.0 and were associated with fewer bleeding complications during the first 3 months after operation.10. Aspirin may reduce the long-term frequency of thromboembolism in patients with bioprosthetic valves.
Similar articles
-
Antithrombotic therapy in patients with mechanical and biological prosthetic heart valves.Chest. 1998 Nov;114(5 Suppl):602S-610S. doi: 10.1378/chest.114.5_supplement.602s. Chest. 1998. PMID: 9822066 Review.
-
Antithrombotic therapy in valvular heart disease--native and prosthetic: the Seventh ACCP Conference on Antithrombotic and Thrombolytic Therapy.Chest. 2004 Sep;126(3 Suppl):457S-482S. doi: 10.1378/chest.126.3_suppl.457S. Chest. 2004. PMID: 15383481 Review.
-
Preliminary experience with aspirin for anticoagulation in children with prosthetic cardiac valves.Ann Thorac Surg. 1982 Jun;33(6):549-53. doi: 10.1016/s0003-4975(10)60811-9. Ann Thorac Surg. 1982. PMID: 6178379
-
Antithrombotic and thrombolytic therapy for valvular disease: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines.Chest. 2012 Feb;141(2 Suppl):e576S-e600S. doi: 10.1378/chest.11-2305. Chest. 2012. PMID: 22315272 Free PMC article.
-
Antiplatelet drugs and the incidence of thromboembolic complications of the St. Jude Medical aortic prosthesis in patients with rheumatic heart disease.J Thorac Cardiovasc Surg. 1986 Jan;91(1):92-8. J Thorac Cardiovasc Surg. 1986. PMID: 3941564
Cited by
-
Plasminogen activators and ischemic stroke: conditions for acute delivery.Semin Thromb Hemost. 2013 Jun;39(4):406-25. doi: 10.1055/s-0033-1338126. Epub 2013 Mar 28. Semin Thromb Hemost. 2013. PMID: 23539414 Free PMC article. Review.
-
Microwave sterilization of bovine pericardium for heart valve applications.J Artif Organs. 2010 Apr;13(1):24-30. doi: 10.1007/s10047-010-0489-9. Epub 2010 Mar 6. J Artif Organs. 2010. Retraction in: J Artif Organs. 2010 Sep;13(3):182. doi: 10.1007/s10047-010-0510-3. PMID: 20213454 Retracted.
-
Biomechanical and morphological stability of acellular scaffolds for tissue-engineered heart valves depends on different storage conditions.J Mater Sci Mater Med. 2018 Jul 3;29(7):106. doi: 10.1007/s10856-018-6106-9. J Mater Sci Mater Med. 2018. PMID: 29971508 Free PMC article.
-
Long-term Anticoagulation Therapy in Prevention of Stroke.Curr Treat Options Neurol. 2002 Nov;4(6):411-416. doi: 10.1007/s11940-002-0008-2. Curr Treat Options Neurol. 2002. PMID: 12354367
-
Morbidity and mortality associated with the interaction of miconazole oral gel and warfarin.Br Dent J. 2018 Jul 27;225(2):129-132. doi: 10.1038/sj.bdj.2018.534. Br Dent J. 2018. PMID: 30050203
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical