Minimizing radiation dose for pediatric body applications of single-detector helical CT: strategies at a large Children's Hospital
- PMID: 11159061
- DOI: 10.2214/ajr.176.2.1760303
Minimizing radiation dose for pediatric body applications of single-detector helical CT: strategies at a large Children's Hospital
Abstract
Adjustments of the standard helical CT protocols for adults can result in reduced radiation dose when imaging children. It is the radiologist's responsibility to critically evaluate the CT techniques used at their institution. Adjustments to CT protocols should be made to choose the appropriate mA and pitch when imaging children.
Comment in
-
Taking care of children: check out the parameters used for helical CT.AJR Am J Roentgenol. 2001 Feb;176(2):287. doi: 10.2214/ajr.176.2.1760287. AJR Am J Roentgenol. 2001. PMID: 11159057 No abstract available.
-
Taking care of children.AJR Am J Roentgenol. 2001 Sep;177(3):715-7. doi: 10.2214/ajr.177.3.1770715b. AJR Am J Roentgenol. 2001. PMID: 11517084 No abstract available.
-
CT as a cause of cancer: what's old is new again.AJR Am J Roentgenol. 2001 Sep;177(3):717. doi: 10.2214/ajr.177.3.1770717. AJR Am J Roentgenol. 2001. PMID: 11517087 No abstract available.
-
Radiation dose on pediatric CT: losing track of time.AJR Am J Roentgenol. 2002 Feb;178(2):507-8. doi: 10.2214/ajr.178.2.1780507b. AJR Am J Roentgenol. 2002. PMID: 11804927 No abstract available.
-
Dose reduction in CT: how low can we go?AJR Am J Roentgenol. 2002 Aug;179(2):299. doi: 10.2214/ajr.179.2.1790299. AJR Am J Roentgenol. 2002. PMID: 12130422 No abstract available.
Similar articles
-
Pediatric Emergency CT Scans at a Children's Hospital and at Community Hospitals: Radiation Technical Factors Are an Important Source of Radiation Exposure.AJR Am J Roentgenol. 2015 Aug;205(2):409-13. doi: 10.2214/AJR.14.13715. Epub 2015 May 22. AJR Am J Roentgenol. 2015. PMID: 26001117
-
Use of a dedicated pediatric CT imaging service associated with decreased patient radiation dose.J Am Coll Radiol. 2012 May;9(5):340-3. doi: 10.1016/j.jacr.2011.12.027. J Am Coll Radiol. 2012. PMID: 22554632
-
Helical CT of the body: a survey of techniques used for pediatric patients.AJR Am J Roentgenol. 2003 Feb;180(2):401-6. doi: 10.2214/ajr.180.2.1800401. AJR Am J Roentgenol. 2003. PMID: 12540442
-
Dose reduction in pediatric hybrid and planar imaging.Q J Nucl Med Mol Imaging. 2010 Aug;54(4):379-88. Q J Nucl Med Mol Imaging. 2010. PMID: 20823806 Review.
-
PET/CT and SPECT/CT dosimetry in children: the challenge to the pediatric imager.Semin Nucl Med. 2007 Sep;37(5):391-8. doi: 10.1053/j.semnuclmed.2007.05.002. Semin Nucl Med. 2007. PMID: 17707244 Review.
Cited by
-
Multislice CT: update on radiation and screening.Eur Radiol. 2003 Dec;13 Suppl 5:M129-33. doi: 10.1007/s00330-003-2107-1. Eur Radiol. 2003. PMID: 14989623 Review.
-
Triple-phase abdomen and pelvis computed tomography: standard unenhanced phase can be replaced with reduced-dose scan.Pol J Radiol. 2018 Apr 22;83:e166-e170. doi: 10.5114/pjr.2018.75682. eCollection 2018. Pol J Radiol. 2018. PMID: 30627230 Free PMC article.
-
Pediatric thoracic CT angiography.Pediatr Radiol. 2005 Jan;35(1):11-25. doi: 10.1007/s00247-004-1348-8. Epub 2004 Nov 23. Pediatr Radiol. 2005. PMID: 15565342
-
Strategies of dose reduction.Pediatr Radiol. 2002 Apr;32(4):293-7. doi: 10.1007/s00247-002-0684-9. Epub 2002 Mar 7. Pediatr Radiol. 2002. PMID: 11956713 No abstract available.
-
Where we were, what has changed, what needs doing: a decade of progress.Pediatr Radiol. 2011 Sep;41 Suppl 2:456-60. doi: 10.1007/s00247-011-2104-5. Epub 2011 Aug 17. Pediatr Radiol. 2011. PMID: 21847722 Review.