Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Jan;80(1):516-30.
doi: 10.1016/S0006-3495(01)76034-1.

Visualizing excitation waves inside cardiac muscle using transillumination

Affiliations

Visualizing excitation waves inside cardiac muscle using transillumination

W T Baxter et al. Biophys J. 2001 Jan.

Abstract

Voltage-sensitive fluorescent dyes have become powerful tools for the visualization of excitation propagation in the heart. However, until recently they were used exclusively for surface recordings. Here we demonstrate the possibility of visualizing the electrical activity from inside cardiac muscle via fluorescence measurements in the transillumination mode (in which the light source and photodetector are on opposite sides of the preparation). This mode enables the detection of light escaping from layers deep within the tissue. Experiments were conducted in perfused (8 mm thick) slabs of sheep right ventricular wall stained with the voltage-sensitive dye di-4-ANEPPS. Although the amplitude and signal-to-noise ratio recorded in the transillumination mode were significantly smaller than those recorded in the epi-illumination mode, they were sufficient to reliably determine the activation sequence. Penetration depths (spatial decay constants) derived from measurements of light attenuation in cardiac muscle were 0.8 mm for excitation (520 +/- 30 nm) and 1.3 mm for emission wavelengths (640 +/- 50 nm). Estimates of emitted fluorescence based on these attenuation values in 8-mm-thick tissue suggest that 90% of the transillumination signal originates from a 4-mm-thick layer near the illuminated surface. A 69% fraction of the recorded signal originates from > or =1 mm below the surface. Transillumination recordings may be combined with endocardial and epicardial surface recordings to obtain information about three-dimensional propagation in the thickness of the myocardial wall. We show an example in which transillumination reveals an intramural reentry, undetectable in surface recordings.

PubMed Disclaimer

References

    1. Photochem Photobiol. 1985 Aug;42(2):153-62 - PubMed
    1. Circ Res. 1993 Mar;72(3):631-50 - PubMed
    1. Prog Clin Biol Res. 1984;170:91-114 - PubMed
    1. Circulation. 1994 Jul;90(1):1 - PubMed
    1. Circulation. 1997 Dec 16;96(12):4392-9 - PubMed

Publication types

Substances

LinkOut - more resources