Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Jan;61(1):1-13.
doi: 10.1006/mvre.2000.2269.

Ocular hemodynamics during isometric exercise

Affiliations

Ocular hemodynamics during isometric exercise

B Kiss et al. Microvasc Res. 2001 Jan.

Abstract

The autoregulatory capacity of the human retina is well documented, but the pressure-flow relationship of the human choroid is still a matter of controversy. Recent data, using laser Doppler flowmetry to measure choroidal blood flow, indicate that the choroid has some autoregulatory potential, whereas most data using other techniques for the assessment of choroidal hemodynamics indicate that the choroidal pressure-flow curve is linear. We used a new laser interferometric technique to characterize choroidal blood flow during isometric exercise. Twenty healthy subjects performed squatting for 6 min during normocapnia and during inhalation of 5% CO2 and 95% air. Ocular fundus pulsation amplitude, flow velocities in the ophthalmic artery, intraocular pressure, and systemic hemodynamics were measured in 2-min intervals. To gain information on choroidal blood flow fundus pulsation amplitude was corrected for changes in flow pulsatility using data from the ophthalmic artery and for changes in pulse rate. Ocular perfusion pressure was calculated from mean arterial pressure and intraocular pressure. The ocular pressure-flow relationship was calculated by sorting data according to ascending ocular perfusion pressure values. In a pilot study in 6 healthy subjects comparable ocular pressure flow relationships were obtained when choroidal blood flow was assessed with the method described above and with laser Doppler flowmetry. In the main study isometric exercise caused a significant increase in mean arterial pressure (56%, P < 0.001), pulse rate (84%, P < 0.001), and intraocular pressure (37%, P 0.004), but decreased fundus pulsation amplitude (-36%, P < 0.001). Significant deviations from baseline choroidal blood flow were observed only at ocular perfusion pressures >69% during normocapnia and 70% during hypercapnia. Our data indicate that during isometric exercise the choroid has a high capacity to keep blood flow constant despite changes in perfusion pressure and that this pressure-flow relationship is not altered by moderate changes in arterial carbon dioxide levels.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources