Use of atmospheric pressure ionization mass spectrometry in enantioselective liquid chromatography
- PMID: 11170248
- DOI: 10.1002/1520-636X(2001)13:2<63::AID-CHIR1000>3.0.CO;2-5
Use of atmospheric pressure ionization mass spectrometry in enantioselective liquid chromatography
Abstract
Recent advances in mass spectrometry have rendered it an attractive and versatile tool in industrial and academic research laboratories. As a part of this rapid growth, a considerable body of literature has been devoted to the application of mass spectrometry in studies involving enantioselectivity, molecular recognition, and supramolecular chemistry. In concert with separation techniques such as capillary electrophoresis and liquid chromatography, mass spectrometry allows rapid characterization of a large array of molecules in complex mixtures. A majority of these findings have been made possible by the introduction of 'soft-ionization' techniques such as electrospray ionization interface. Other techniques such as atmospheric pressure chemical ionization mass spectrometry have been widely used as a rugged interface for quantitative liquid chromatography-mass spectrometry. Herein, we present a brief overview of the above techniques accompanied with several examples of enantioselective capillary electrophoresis- and liquid chromatography-mass spectrometry in drug discovery and development. Although the emphasis of this article is on quantitative enantiomeric chromatography-mass spectrometry, we envisage that similar strategies are adaptable in qualitative studies.
Copyright 2001 Wiley-Liss, Inc.
Similar articles
-
Chiral liquid chromatography-tandem mass spectrometric methods for stereoisomeric pharmaceutical determinations.J Chromatogr B Analyt Technol Biomed Life Sci. 2005 Jun 5;820(1):1-8. doi: 10.1016/j.jchromb.2005.02.012. Epub 2005 Apr 19. J Chromatogr B Analyt Technol Biomed Life Sci. 2005. PMID: 15866486 Review.
-
Liquid chromatography/atmospheric pressure ionization-mass spectrometry in drug metabolism studies.J Mass Spectrom. 2003 Apr;38(4):357-72. doi: 10.1002/jms.481. J Mass Spectrom. 2003. PMID: 12717747 Review.
-
Effect of eluent on the ionization process in liquid chromatography-mass spectrometry.J Chromatogr A. 2009 Jan 23;1216(4):685-99. doi: 10.1016/j.chroma.2008.08.095. Epub 2008 Sep 2. J Chromatogr A. 2009. PMID: 18799161 Review.
-
Liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry enantiomeric separation of dl-threo-methylphenidate, (Ritalin) using a macrocyclic antibiotic as the chiral selector.Rapid Commun Mass Spectrom. 1999;13(20):2054-62. doi: 10.1002/(SICI)1097-0231(19991030)13:20<2054::AID-RCM749>3.0.CO;2-5. Rapid Commun Mass Spectrom. 1999. PMID: 10510420
-
Characterization of the chemical composition of a block copolymer by liquid chromatography/mass spectrometry using atmospheric pressure chemical ionization and electrospray ionization.Rapid Commun Mass Spectrom. 2007;21(16):2629-37. doi: 10.1002/rcm.3114. Rapid Commun Mass Spectrom. 2007. PMID: 17639566
Cited by
-
Identification of anionic supramolecular complexes of sulfonamide receptors with Cl-, NO3-, Br-, and I- by APCI-MS.J Am Soc Mass Spectrom. 2005 Aug;16(8):1377-83. doi: 10.1016/j.jasms.2005.04.008. J Am Soc Mass Spectrom. 2005. PMID: 27035012 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials