On the IVUS plaque volume error in coronary arteries when neglecting curvature
- PMID: 11179614
- DOI: 10.1016/s0301-5629(00)00295-7
On the IVUS plaque volume error in coronary arteries when neglecting curvature
Abstract
Plaque volume determined by common linear 3-D IVUS analysis systems will show under- or overestimation in curved vessel segments because these systems approximate the true 3-D transducer pull-back trajectory by a straight line. We developed a mathematical model that showed that the error is primarily dependent on the curvature of the pull-back trajectory and not on vessel tortuosity. Furthermore, we measured this error in vivo in the coronary arteries of 15 patients, comparing the plaque volume using a true 3-D reconstruction method with that of the linear approach. The in vivo plaque volume error ranged from 2.3% to -1.2% for 15 coronary segments with lengths ranging from 38.8 to 89.1 mm (62.2 +/- 13 mm). The volume error introduced by linear 3-D IVUS analysis systems is dependent on the curvature of the pull-back trajectory. The error measured in vivo was small and inversely related to segment length.
Similar articles
-
Impact of vessel curvature on the accuracy of three-dimensional intravascular ultrasound: validation by phantoms and coronary segments.J Am Soc Echocardiogr. 2002 Aug;15(8):823-30. doi: 10.1067/mje.2002.120700. J Am Soc Echocardiogr. 2002. PMID: 12174352
-
In vivo comparative study of linear versus geometrically correct three-dimensional reconstruction of coronary arteries.Am J Cardiol. 2008 Jan 15;101(2):263-7. doi: 10.1016/j.amjcard.2007.07.070. Am J Cardiol. 2008. PMID: 18178419
-
A novel three-dimensional quantitative coronary angiography system: In-vivo comparison with intravascular ultrasound for assessing arterial segment length.Catheter Cardiovasc Interv. 2010 Aug 1;76(2):291-8. doi: 10.1002/ccd.22502. Catheter Cardiovasc Interv. 2010. PMID: 20665880
-
Three-dimensional reconstruction of coronary arteries with intravascular ultrasound.Herz. 1995 Aug;20(4):277-89. Herz. 1995. PMID: 7557831 Review.
-
[The form of atherosclerotic coronary plaques: pathoanatomic concepts and new insights using intravascular ultrasound].Z Kardiol. 1994 Oct;83(10):717-26. Z Kardiol. 1994. PMID: 7810185 Review. German.
Cited by
-
Volumetric intravascular ultrasound measurements in coronary arteries.Int J Cardiovasc Imaging. 2003 Feb;19(1):59-61. doi: 10.1023/a:1021799703309. Int J Cardiovasc Imaging. 2003. PMID: 12602483 No abstract available.
-
The Evolution of Data Fusion Methodologies Developed to Reconstruct Coronary Artery Geometry From Intravascular Imaging and Coronary Angiography Data: A Comprehensive Review.Front Cardiovasc Med. 2020 Mar 31;7:33. doi: 10.3389/fcvm.2020.00033. eCollection 2020. Front Cardiovasc Med. 2020. PMID: 32296713 Free PMC article. Review.
-
Advanced contour detection for three-dimensional intracoronary ultrasound: a validation--in vitro and in vivo.Int J Cardiovasc Imaging. 2002 Aug;18(4):235-48. doi: 10.1023/a:1015551920382. Int J Cardiovasc Imaging. 2002. PMID: 12123316
-
Assessment of potential relationship between wall shear stress and arterial wall response after bare metal stent and sirolimus-eluting stent implantation in patients with diabetes mellitus.Int J Cardiovasc Imaging. 2008 Apr;24(4):357-64. doi: 10.1007/s10554-007-9274-0. Epub 2007 Oct 31. Int J Cardiovasc Imaging. 2008. PMID: 17972162 Clinical Trial.
-
Intra- and interobserver variability in detection and assessment of calcified and noncalcified coronary artery plaques using 64-slice computed tomography: variability in coronary plaque measurement using MSCT.Int J Cardiovasc Imaging. 2008 Oct;24(7):735-42. doi: 10.1007/s10554-008-9299-z. Epub 2008 Jun 28. Int J Cardiovasc Imaging. 2008. PMID: 18587663
MeSH terms
LinkOut - more resources
Full Text Sources
Medical