Simultaneous technetium-99 MAG(3), iodine-131-orthoiodohippurate and iodine-125 iothalamate clearance and biodistribution after bolus injection in rats
- PMID: 11180197
- DOI: 10.1002/1099-081x(200007)21:5<181::aid-bdd227>3.0.co;2-j
Simultaneous technetium-99 MAG(3), iodine-131-orthoiodohippurate and iodine-125 iothalamate clearance and biodistribution after bolus injection in rats
Abstract
A bolus injection multiple blood sampling method was developed for the simultaneous measurement of blood and plasma clearance of three radiopharmaceuticals in rats. Technetium-99m mercaptoacetyltriglycine ([(99m)Tc]MAG(3)) and iodine-131-orthoiodohippurate ([(131)I]OIH) were used as makers of effective renal blood flow (ERBF), and iodine-125 iothalamate ([(125)I]IOT) was used as a marker of glomerular filtration rate (GFR). These methods can be easily performed in rats without arterial catheterization. Tissue biodistribution was studied in four groups of rats subjected to the following: group A, renal pedicle isolation (sham-operated); group B, ligature of one kidney pedicle; group C, ligature of both renal pedicles; and group D, ligature of both kidney pedicles and the bile duct. Renal clearance of [(99m)Tc]MAG(3) was greater than [(131)I]OIH and both agents were cleared faster than ([(125)I]-IOT). Either of the two markers of ERBF may be used in experimental studies, but it should be borne in mind that these are relative measurements of kidney performance. [(99m)Tc]MAG(3) and [(125)I]-IOT showed bile excretion in healthy rats, so they cannot completely fulfill the requirements for use as markers of ERBF. When renal function was impaired experimentally, [(99m)Tc]MAG(3) and [(125)I]-IOT were excreted in bile and [(131)I]OIH was secreted in the intestine. Thus, while the markers of ERBF and GFR may be reliable under normal physiological conditions, they may give progressively more erroneous values as renal function deteriorates.
Copyright 2000 John Wiley & Sons, Ltd.
Similar articles
-
99mTc-MAG3 kinetics in the normal pig. A comparison to 131I-OIH and 125I-iothalamate after single injection and during continuous infusion.Clin Physiol. 1995 Jan;15(1):57-71. doi: 10.1111/j.1475-097x.1995.tb00430.x. Clin Physiol. 1995. PMID: 7712693
-
Comparison of 99mTc-mercaptoacetyltriglycine and [131I]-o-iodohippurate elimination in perfused rat kidney.Nucl Med Biol. 2003 Jan;30(1):45-9. doi: 10.1016/s0969-8051(02)00377-3. Nucl Med Biol. 2003. PMID: 12493542
-
Clearance and renal extraction of technetium-99m-L,L-ethylenedicysteine, I-131-ortho-iodohippurate and I-125-iothalamate in pigs.Clin Physiol. 1999 Jul;19(4):338-43. doi: 10.1046/j.1365-2281.1999.00186.x. Clin Physiol. 1999. PMID: 10451795
-
Quantitative scintigraphic parameters for the assessment of renal transplant patients.Eur J Radiol. 1998 Oct;28(3):256-69. doi: 10.1016/s0720-048x(97)00179-4. Eur J Radiol. 1998. PMID: 9881262 Review.
-
Renal nuclear medicine: a review.Vet Radiol Ultrasound. 1999 Nov-Dec;40(6):572-87. doi: 10.1111/j.1740-8261.1999.tb00883.x. Vet Radiol Ultrasound. 1999. PMID: 10608684 Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials