Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2000 Dec;38(12):933-8.
doi: 10.1055/s-2000-10025.

Modified percutaneous endoscopic gastrostomy (PEG) with gastropexy--early experience with a new introducer technique

Affiliations

Modified percutaneous endoscopic gastrostomy (PEG) with gastropexy--early experience with a new introducer technique

A J Dormann et al. Z Gastroenterol. 2000 Dec.

Abstract

Objective: The Cliny PEG 13 has been available since 1999 for clinical use in the modified introducer technique in combination with endoscopically controlled gastropexy. Data on indication, insertion technique and safety have not yet been reported in the literature.

Methods: During the time period from January 1999 to June 2000, from a total of 457 patients receiving a PEG 27 (5.9%) subjects, in whom the insertion of a PEG by means of pull-through technique was impossible or only in combination with an intervention e.g. bougienage were included in this prospective study. Each patient received a Cliny PEG 13 by means of introducer technique with endoscopically controlled double gastropexy. Tumor patients with severe stenosis made up more than 90% of the cases. The insertion and 30 day follow-up were performed using a standardized protocol. Method-related and unrelated complications were recorded.

Results: PEG insertion was successful in all patients without additional intervention. We did not see any method-related complications. The peri-interventional local infection rate was 3.7%. One patient died during the 30-day follow-up period as a result of progression of the underlying disease. No further complications occurred in long term follow-up.

Conclusions: Our results show that the Cliny PEG 13 is a safe technique and an alternative to other methods and surgical procedures in patients in whom a PEG was not applicable by means of the pull-through technique. Larger case numbers and the use in other patient collectives will have to prove these initial results.

PubMed Disclaimer

LinkOut - more resources