Abstract
Background: Previous studies have shown that the cup:disc (C/D) ratio has limited sensitivity and specificity. Improved sensitivity and specificity has been found with combinations of disc parameters using stereophotography or disc imaging, but the extent to which these studies reflect what can be achieved by direct assessment is unclear. The purpose of this paper is to report the sensitivities and specificities of a range of disc parameters, both in isolation and in combination, as graded during clinical examination with direct ophthalmoscopy.
Methods: Sixty-seven patients with newly diagnosed primary open angle glaucoma and 145 non-glaucomatous subjects were examined by direct ophthalmoscopy. The following features of the optic disc were graded: vertical and horizontal C/D ratios (uncorrected for disc size), narrowest rim width, presence/absence of disc haemorrhage, focal pallor of the neuroretinal rim, parapapillary atrophy, steepness of the cup-edge and presence/absence of baring of the lamina cribrosa. Subjects were validated as glaucomatous/non-glaucomatous on the basis of visual fields, independently of the results of optic disc gradings. Multiple logistic regression modelling was used to evaluate the effectiveness of combinations of disc parameters.
Results: Sensitivities and specificities are limited for all features when considered in isolation. The 'cupping' parameters have the highest sensitivities and specificities but no single cut-off criterion for these parameters has both high sensitivity and specificity. Multiple logistic regression modelling indicated that two disc parameters in combination, narrowest rim width and parapapillary atrophy, were independently associated with glaucoma and achieved best prediction. Combining information from these parameters achieved a sensitivity of 81% (95% CI = 69-89%) and a specificity of 90% (95% CI = 84-95%), a level of discrimination that is not significantly better than narrowest rim width alone in terms of area under the receiver operator characteristic (ROC) curve.
Conclusion: Disc assessment during clinical examination with direct ophthalmoscopy can achieve comparable sensitivities and specificities with those previously reported for stereophotographic assessment or visual fields screening. However, since the diagnostic accuracy of disc assessment in isolation is inadequate for screening, a combined test strategy is necessary.
Similar articles
-
Ranking of optic disc variables for detection of glaucomatous optic nerve damage.Invest Ophthalmol Vis Sci. 2000 Jun;41(7):1764-73. Invest Ophthalmol Vis Sci. 2000. PMID: 10845597
-
Optic disc and early glaucomatous visual field loss.Korean J Ophthalmol. 1990 Dec;4(2):82-91. doi: 10.3341/kjo.1990.4.2.82. Korean J Ophthalmol. 1990. PMID: 2092165
-
Optic disc imaging in perimetrically normal eyes of glaucoma patients with unilateral field loss.Trans Am Ophthalmol Soc. 2006;104:202-11. Trans Am Ophthalmol Soc. 2006. PMID: 17471341 Free PMC article.
-
[Clinical evaluation of the optic disc in glaucoma].Ophthalmologe. 2016 Oct;113(10):816-823. doi: 10.1007/s00347-016-0331-8. Ophthalmologe. 2016. PMID: 27448220 Review. German.
-
Spotlight on the Disc-Damage Likelihood Scale (DDLS).Clin Ophthalmol. 2021 Oct 7;15:4059-4071. doi: 10.2147/OPTH.S284618. eCollection 2021. Clin Ophthalmol. 2021. PMID: 34675474 Free PMC article. Review.
Cited by
-
The role of clinical parapapillary atrophy evaluation in the diagnosis of open angle glaucoma.Clin Ophthalmol. 2010 Sep 7;4:971-6. doi: 10.2147/opth.s12420. Clin Ophthalmol. 2010. PMID: 20856591 Free PMC article.
-
Cost-effectiveness of glaucoma interventions in Barbados and Ghana.Optom Vis Sci. 2011 Jan;88(1):155-63. doi: 10.1097/OPX.0b013e3181fc30f3. Optom Vis Sci. 2011. PMID: 21076360 Free PMC article.
-
Spectrum of ocular diseases in patients attending eye camps in Andaman and Nicobar.Med J Armed Forces India. 2016 Jan;72(1):45-7. doi: 10.1016/j.mjafi.2015.04.001. Epub 2015 Jun 9. Med J Armed Forces India. 2016. PMID: 26900222 Free PMC article.
-
The cost-effectiveness of Welcome to Medicare visual acuity screening and a possible alternative welcome to medicare eye evaluation among persons without diagnosed diabetes mellitus.Arch Ophthalmol. 2012 May;130(5):607-14. doi: 10.1001/archopthalmol.2011.1921. Arch Ophthalmol. 2012. PMID: 22232367 Free PMC article.
-
Eyesi direct ophthalmoscope simulator: an effective training tool for medical undergraduates.BMC Med Educ. 2024 Jul 20;24(1):783. doi: 10.1186/s12909-024-05780-w. BMC Med Educ. 2024. PMID: 39033099 Free PMC article. Clinical Trial.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources