[Full-field digital mammography]
- PMID: 11199437
- DOI: 10.1055/s-2000-9210
[Full-field digital mammography]
Abstract
Due to the extremely high image quality requirements in mammography, there has for a long time been no adequate digital alternative to conventional film-screen mammography. The longest experience so far exists with digital mammography on the basis of storage phosphor (CR) systems. However, at normal dose this technique has a relatively poor signal-to-noise ratio and has not found general acceptance. Recently three novel systems for digital mammography by the companies Fischer (slot-scan detector), Trex (CCD-array), and GE (amorphous silicon detector) have been introduced and are currently under clinical investigation. The main advantage of digital mammography is the linear relationship between dose and detector signal with the possibility of a tailored optimization of image contrast. Other advantages include digital image storage, telemammography, and computer-assisted diagnosis.
Similar articles
-
[Experimental studies on image quality in conventional film screen system, digital phosphor storage plate mammography in mangnification technique and digital mammography in CCD-technique].Rofo. 2000 Dec;172(12):965-8. doi: 10.1055/s-2000-9227. Rofo. 2000. PMID: 11199438 German.
-
Experimental investigations of image quality in X-ray mammography with conventional screen film system (SFS), digital phosphor storage plate in/without magnification technique (CR) and digital CCD-technique (CCD).Rontgenpraxis. 2001;54(4):123-6. Rontgenpraxis. 2001. PMID: 11883115
-
ATMTN: a telemammography network architecture.IEEE Trans Biomed Eng. 2002 Dec;49(12):1438-43. doi: 10.1109/TBME.2002.805556. IEEE Trans Biomed Eng. 2002. PMID: 12542239
-
Digital mammography for screening and diagnosis of breast cancer: an overview.JBR-BTR. 2007 May-Jun;90(3):163-6. JBR-BTR. 2007. PMID: 17696081 Review.
-
Digital mammography: are there advantages in screening for breast cancer?Acad Radiol. 2008 Apr;15(4):401-7. doi: 10.1016/j.acra.2008.01.004. Acad Radiol. 2008. PMID: 18342763 Review.
Cited by
-
[Radiological diagnosis of mammary carcinomas. I: pathology and x-ray mammography].Radiologe. 2004 May;44(5):517-38; quiz 539-40. doi: 10.1007/s00117-004-1060-6. Radiologe. 2004. PMID: 15250098 Review. German.
-
Comparison of standard mammography with digital mammography and digital infrared thermal imaging for breast cancer screening.J Turk Ger Gynecol Assoc. 2010 Sep 1;11(3):152-7. doi: 10.5152/jtgga.2010.24. eCollection 2010. J Turk Ger Gynecol Assoc. 2010. PMID: 24591923 Free PMC article. Review.
-
Impact of breast density on computer-aided detection in full-field digital mammography.J Digit Imaging. 2006 Sep;19(3):258-63. doi: 10.1007/s10278-006-0592-x. J Digit Imaging. 2006. PMID: 16741664 Free PMC article.
-
[Workflow in digital screening mammography].Radiologe. 2008 Apr;48(4):335-44. doi: 10.1007/s00117-008-1633-x. Radiologe. 2008. PMID: 18305919 Review. German.
-
[Clinical results of digital mammography].Radiologe. 2005 Mar;45(3):255-63. doi: 10.1007/s00117-005-1175-4. Radiologe. 2005. PMID: 15744483 Review. German.
Publication types
MeSH terms