Mechanical properties and wear behavior of light-cured packable composite resins
- PMID: 11203521
- DOI: 10.1016/s0109-5641(99)00082-2
Mechanical properties and wear behavior of light-cured packable composite resins
Abstract
Objectives: Determination of flexural strength, flexural modulus, fracture toughness and wear resistance of three packable composites (Solitaire, Surefil, ALERT) and a packable ormocer (Definite) in comparison with an advanced hybrid composite (Tetric Ceram) and an ion-releasing composite (Ariston pHc).
Methods: Flexural strength, flexural modulus and fracture toughness of each material were determined in three-point bending (each test n = 10). Single-edge notched-bend specimens were used to evaluate the fracture toughness (K1C). Wear of the materials (n = 8) was determined in a pin-on-block-design with a spherical Degusit antagonist at 50 N vertical load and quantified by a replica technique using a 3D-laser scanner. Replicas were made after 6000, 10,000, 30,000 and 50,000 load cycles. The mean wear rate (MWR (micron 3 cycle-1)) was obtained by a linear regression analysis in the steady-state of the time-wear-curve. All results were statistically analyzed with ANOVA and post hoc Tukey HSD tests (p < 0.05).
Results: ALERT exhibited the highest flexural modulus (12.5 +/- 2.1 GPa) and K1C (2.3 +/- 0.2 MN m-3/2), but the lowest wear resistance (8275 micron 3 cycle-1). Solitaire presented the highest wear resistance (1591 micron 3 cycle-1), but significantly lower flexural strength (81.6 +/- 10.0 MPa), flexural modulus (4.4 +/- 0.3 GPa), and K1C (1.4 +/- 0.2 MN m-3/2) than all other materials. Surefil revealed a significantly higher flexural modulus (9.3 +/- 0.9 GPa) and wear resistance (3028 micron 3 cycle-1) than Tetric Ceram (6.8 +/- 0.5 GPa; 5417 micron 3 cycle-1) and Ariston pHc (7.3 +/- 0.8 GPa; 7194 micron 3 cycle-1).
Significance: The tested packable composite resins differed significantly in their mechanical properties. This study suggested that fracture and wear behavior of the composite resins are highly influenced by the filler system. Overall, Surefil demonstrated good fracture mechanics parameters and a low wear rate.
Similar articles
-
Mechanical properties of new composite restorative materials.J Biomed Mater Res. 2000;53(4):353-61. doi: 10.1002/1097-4636(2000)53:4<353::aid-jbm9>3.0.co;2-b. J Biomed Mater Res. 2000. PMID: 10898876
-
Mechanical properties of contemporary composite resins and their interrelations.Dent Mater. 2013 Aug;29(8):e132-41. doi: 10.1016/j.dental.2013.04.025. Epub 2013 Jun 19. Dent Mater. 2013. PMID: 23790281
-
Evaluation of resin composite materials. Part I: in vitro investigations.Am J Dent. 2005 Feb;18(1):23-7. Am J Dent. 2005. PMID: 15810477
-
Packable composites: overview and technical considerations.J Esthet Dent. 1999;11(5):234-49. doi: 10.1111/j.1708-8240.1999.tb00405.x. J Esthet Dent. 1999. PMID: 10825879 Review.
-
The Hardness and Strength Properties of WC-Co Composites.Materials (Basel). 2011 Jul 14;4(7):1287-1308. doi: 10.3390/ma4071287. Materials (Basel). 2011. PMID: 28824143 Free PMC article. Review.
Cited by
-
Fluorinated Montmorillonite Composite Resin as a Dental Pit and Fissure Sealant.Polymers (Basel). 2019 Sep 20;11(10):1535. doi: 10.3390/polym11101535. Polymers (Basel). 2019. PMID: 31547022 Free PMC article.
-
Clinical evaluation of two packable posterior composites: 2-year follow-up.Clin Oral Investig. 2006 Sep;10(3):197-203. doi: 10.1007/s00784-006-0059-y. Epub 2006 Jul 6. Clin Oral Investig. 2006. PMID: 16823554 Clinical Trial.
-
Glass Fiber Reinforced Composite Orthodontic Retainer: In Vitro Effect of Tooth Brushing on the Surface Wear and Mechanical Properties.Materials (Basel). 2020 Feb 25;13(5):1028. doi: 10.3390/ma13051028. Materials (Basel). 2020. PMID: 32106404 Free PMC article.
-
Micro-sized erosions in a nanofilled composite after repeated acidic beverage exposures: consequences of clusters dislodgments.J Appl Oral Sci. 2014 Sep-Oct;22(5):373-81. doi: 10.1590/1678-775720130658. Epub 2014 Jul 4. J Appl Oral Sci. 2014. PMID: 25004054 Free PMC article.
-
Microleakage and Marginal Integrity of Ormocer/Methacrylate-Based Bulk-Fill Resin Restorations in MOD Cavities: SEM and Stereomicroscopic Evaluation.Polymers (Basel). 2023 Mar 30;15(7):1716. doi: 10.3390/polym15071716. Polymers (Basel). 2023. PMID: 37050330 Free PMC article.