Applications of a copper microparticle-modified carbon fiber microdisk array electrode for the simultaneous determination of aminoglycoside antibiotics by capillary electrophoresis
- PMID: 11206799
- DOI: 10.1016/s0021-9673(00)00985-7
Applications of a copper microparticle-modified carbon fiber microdisk array electrode for the simultaneous determination of aminoglycoside antibiotics by capillary electrophoresis
Abstract
A copper microparticle-modified carbon fiber microdisk array electrode was fabricated and employed in capillary electrophoresis for the simultaneous determination of the five aminoglycoside antibiotics (AGs) including netilmicin, tobramycin, lincomycin, kanamycin and amikacin. The array electrode exhibited high catalytic activity for AGs, good reproducibility and stability. Under the optimum separation conditions (separation voltage of 6.2 kV, electrophoretic medium of 125 mM NaOH), the five AGs above were baseline separated within 20 min. At a working electrode potential of 0.7 V (versus saturated calomel electrode), the calibration curves were linear over two orders of magnitude of concentration, and the detection limits (SIN=3) were below 2 microM except for lincomycin (6.7 microM). The developed method was successfully employed for the simultaneous determination of the five AGs studied in pharmaceutical injections. The feasibility of this method for the simultaneous determination of lincomycin, kanamycin and amikacin in urine sample was also demonstrated.
Similar articles
-
Simultaneous determination of polycarboxylic acids by capillary electrophoresis with a copper electrode.J Chromatogr A. 2000 Jan 21;867(1-2):261-9. doi: 10.1016/s0021-9673(99)01083-3. J Chromatogr A. 2000. PMID: 10670726
-
Simultaneous determination of purine bases, ribonucleosides and ribonucleotides by capillary electrophoresis-electrochemistry with a copper electrode.J Chromatogr A. 1997 Jan 31;760(2):227-33. doi: 10.1016/s0021-9673(96)00776-5. J Chromatogr A. 1997. PMID: 9102136
-
Measurement of chloramphenicol by capillary zone electrophoresis following end-column amperometric detection at a carbon fiber micro-disk array electrode.J Chromatogr B Biomed Sci Appl. 2000 May 12;741(2):155-62. doi: 10.1016/s0378-4347(00)00049-9. J Chromatogr B Biomed Sci Appl. 2000. PMID: 10872585
-
Quantitation of caffeine by capillary zone electrophoresis with end-column amperometric detection at a carbon microdisk array electrode.J Chromatogr Sci. 2000 Jan;38(1):11-5. doi: 10.1093/chromsci/38.1.11. J Chromatogr Sci. 2000. PMID: 10654786
-
High-performance liquid chromatographic analysis of aminoglycoside antibiotics.J Chromatogr A. 1998 Jul 3;812(1-2):141-50. doi: 10.1016/s0021-9673(98)00342-2. J Chromatogr A. 1998. PMID: 9691315 Review.
Cited by
-
Lattice matching enables construction of CaS@NaYF4 heterostructure with synergistically enhanced water resistance and luminescence for antibiotic detection.Mikrochim Acta. 2024 Jul 26;191(8):485. doi: 10.1007/s00604-024-06568-x. Mikrochim Acta. 2024. PMID: 39060720
-
Simple, rapid, sensitive, selective and label-free lincomycin detection by using HAuCl4 and NaOH.RSC Adv. 2019 Sep 9;9(48):28248-28252. doi: 10.1039/c9ra04095a. eCollection 2019 Sep 3. RSC Adv. 2019. PMID: 35530481 Free PMC article.
-
Aptamer based voltammetric determination of ampicillin using a single-stranded DNA binding protein and DNA functionalized gold nanoparticles.Mikrochim Acta. 2017 Dec 20;185(1):68. doi: 10.1007/s00604-017-2566-8. Mikrochim Acta. 2017. PMID: 29594557
-
The Supramolecular Self-Assembly of Aminoglycoside Antibiotics and their Applications.ChemistryOpen. 2019 Aug 26;8(9):1154-1166. doi: 10.1002/open.201900193. eCollection 2019 Sep. ChemistryOpen. 2019. PMID: 31497469 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical