A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award
- PMID: 11222887
- DOI: 10.1054/arth.2001.20540
A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award
Abstract
Increasing cross-linking has been shown in vitro and in vivo to improve markedly the wear resistance of ultra-high-molecular-weight polyethylene (UHMWPE). The reduction in the mechanical properties of polyethylene under certain methods used to produce cross-linking has been a concern, however. These reductions are known to result from the processes used to increase the cross-link density and could affect the device performance in vivo. We present a novel method of increasing the cross-link density of UHMWPE in which UHMWPE is irradiated in air at an elevated temperature with a high-dose-rate electron beam and subsequently is melt-annealed. This treatment improves markedly the wear resistance of the polymer as tested in a hip simulator, while maintaining the mechanical properties of the material within national and international standards. This method leads to the absence of detectable free radicals in the polymer and, as a result, excellent resistance to oxidation of the polymer.
Similar articles
-
The effect of real-time aging on the oxidation and wear of highly cross-linked UHMWPE acetabular liners.Biomaterials. 2006 Mar;27(9):1980-7. doi: 10.1016/j.biomaterials.2005.10.002. Epub 2005 Nov 4. Biomaterials. 2006. PMID: 16271756
-
Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions.Biomaterials. 2005 Jun;26(16):3259-67. doi: 10.1016/j.biomaterials.2004.07.070. Biomaterials. 2005. PMID: 15603821
-
A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene.J Arthroplasty. 2001 Dec;16(8):1018-23. doi: 10.1054/arth.2001.27234. J Arthroplasty. 2001. PMID: 11740757
-
Implant wear mechanisms--basic approach.Biomed Mater. 2008 Dec;3(4):042001. doi: 10.1088/1748-6041/3/4/042001. Epub 2008 Sep 25. Biomed Mater. 2008. PMID: 18824778 Review.
-
Highly cross-linked polyethylene bearing surfaces in total hip arthroplasty.J Surg Orthop Adv. 2008 Spring;17(1):27-33. J Surg Orthop Adv. 2008. PMID: 18284901 Review.
Cited by
-
Total Hip Arthroplasty Using Modular Trabecular Metal Acetabular Components for Failed Treatment of Acetabular Fractures: A Mid-term Follow-up Study.Chin Med J (Engl). 2016 Apr 20;129(8):903-8. doi: 10.4103/0366-6999.179793. Chin Med J (Engl). 2016. PMID: 27064033 Free PMC article.
-
Is There a Difference in Revision Risk Between Metal and Ceramic Heads on Highly Crosslinked Polyethylene Liners?Clin Orthop Relat Res. 2017 May;475(5):1349-1355. doi: 10.1007/s11999-016-4966-1. Clin Orthop Relat Res. 2017. PMID: 27385222 Free PMC article.
-
An in vivo evaluation of bone response to three implant surfaces using a rabbit intramedullary rod model.J Orthop Surg Res. 2010 Aug 16;5:57. doi: 10.1186/1749-799X-5-57. J Orthop Surg Res. 2010. PMID: 20712889 Free PMC article.
-
Using a patterned microtexture to reduce polyethylene wear in metal-on-polyethylene prosthetic bearing couples.Wear. 2017 Dec 15;392-393:77-83. doi: 10.1016/j.wear.2017.09.014. Epub 2017 Sep 22. Wear. 2017. PMID: 29358840 Free PMC article.
-
Wear of highly crosslinked polyethylene acetabular components.Acta Orthop. 2015 Apr;86(2):159-68. doi: 10.3109/17453674.2014.972890. Epub 2014 Oct 10. Acta Orthop. 2015. PMID: 25301435 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources